6. Clean the filter frame and the supporting sur-
face of the filter frame with a damp cloth.
7. Fit the new flat fold filter. During insertion, en-
sure that the flat fold filter is flush on all sides.
8. Insert the filter frame.
9. Close the filter cover until it audibly latches into
place.
Changing the fleece filter bag
1. Unlock and remove the suction head.
2. Pull the fleece filter bag out to the rear.
Figure C
3. Fold in the lock latch and seal the fleece filter
bag tight.
4. Dispose of the used fleece filter bag in accord-
ance with statutory regulations.
5. Fit the new fleece filter bag.
6. Fit and lock the suction head.
Cleaning the electrodes
1. Unlock and remove the suction head.
2. Clean the electrodes with a brush.
3. Fit and lock the suction head.
Troubleshooting guide
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Note
The device must be switched off immediately if a
malfunction occurs (e.g. filter breakage). The mal-
function must be eliminated before switching the
device on again.
Suction turbine does not start up
1. Check the socket and the power supply fuse.
2. Check the mains cable, mains plug and elec-
trodes on the device.
3. Switch on the device.
Suction turbine switches off
1. Empty the container.
Suction turbine does not switch on again after
emptying the container
1. Switch off the device, wait for 5 seconds and
then switch on again after waiting for 5 sec-
onds.
2. Clean the electrodes with a brush.
Suction power decreases
1. Remove any blockages from the suction nozzle,
suction pipe, suction hose or flat fold filter.
2. Change the filled fleece filter bag.
3. Press the semi-automatic filter dedusting button
5x with the device switched on.
4. Correctly engage the filter cover.
5. Replace the flat fold filter.
Escaping dust when vacuuming
1. Check that the flat fold filter is correctly fitted
and correct if necessary.
Figure H
2. Replace the flat fold filter.
The automatic switch-off mechanism (wet vacuum
cleaning) does not trigger
1. Clean the electrodes with a brush.
2. Continuously monitor the filling level when vac-
uuming non-conductive liquids.
Semi-automatic filter dedusting not working
1. Suction hose not connected.
Semi-automatic filter dedusting does not switch off
1. Contact Customer Service.
Semi-automatic filter dedusting cannot be switched
on
1. Contact Customer Service.
Customer Service department
If the malfunction cannot be corrected, the device
must be checked by the Customer Service depart-
ment.
 For this Würth vacuum cleaner, we offer a guar-
antee in accordance with the statutory/coun-
try-specific provisions from date of purchase (in-
voice or delivery note is required as proof). Any
damage that has occurred will be resolved by
replacement delivery or repair.
 The guarantee excludes damage resulting from
normal wear, overloading or improper han-
dling.
 Complaints can only be accepted if the vacuum
cleaner is returned fully assembled to a Würth
branch, your Würth Sales Representative or
Würth Master Service.