Removing the fleece filter bag
The fleece filter bag must always be removed
when vacuuming wet substances.
1. Unlock and remove the suction head.
2. Pull the fleece filter bag out to the rear.
Figure C
3. Fold in the lock latch and seal the fleece filter
bag tight.
4. Dispose of the used fleece filter bag in accord-
ance with statutory regulations.
5. Fit and lock the suction head.
General
We recommend not using the "Semi-automatic
filter dedusting" function button when vacuum-
ing wet dirt with the crevice nozzle or when
sucking mainly water out of a container.
The device switches off automatically when the
maximum fluid level is reached.
When vacuuming non-conductive liquids (e.g.
drill emulsion, oils and grease) the device does
not automatically switch off when the container
is full. The filling level must be continuously mon-
itored and the container emptied on a timely
basis.
On completion of wet vacuum cleaning: Clean
the electrodes with a brush. Clean the contain-
er with a moist cloth and dry it off.
Clip connection
The suction hose is equipped with a clip system. All
accessory parts with a nominal width of 35 mm
can be connected.
Figure D
Operation
Switching on the device
1. Connect the mains plug.
2. Switch on the device at the turn switch.
Semi-automatic filter dedusting
Note
Actuating the semi-automatic filter dedusting every
5-10 minutes extends the working time of the flat
fold filter.
Note
The semi-automatic filter dedusting can only be
switched on when the device is switched on.
1. Press the semi-automatic filter dedusting button
5x. The flat fold filter is then cleaned by a blast
of air (pulsing noise).
2. Power dedusting (for particularly severe con-
tamination of the flat fold filter): Close off the
suction pipe or angle piece with your hand and
press the semi-automatic filter dedusting button
5x with the device switched on.
Figure E
Switching off the device
1. Press the semi-automatic filter dedusting button
5x.
2. Switch off the device at the turn switch.
3. Pull out the mains plug.
Each time after use
1. Empty the container.
2. Vacuum off the inside and outside of the device
and clean with a moist cloth.
Storing the device
1. Store the suction hose and mains cable as
shown in the illustration.
Figure F
2. Store the device in a dry room and secure it
against unauthorised use.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during trans-
port.
1. Remove the suction hose with floor nozzle from
the support. Carry the device by the carrying
handle and suction pipe.
2. When transporting the device in vehicles, se-
cure it to prevent it from slipping or overturning
in accordance with the respective valid guide-
lines.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during stor-
age.
The device may only be operated indoors.
English
Transport
Storage
17