NOTE! To prevent the risk of fire, the unit has to be installed in accordance with the applicable
standards and technical rules indicated further in this user manual. Its installation should be
carried out by professional and skilled workforce. The unit is EN 13240 compliant and CE cer-
tified.
Always observe the laws applicable to the place of installation. First make sure that the flue is
suitable.
General
The unit has to be installed in accordance with applicable building standards. The stove has to be
placed within a safe distance from all combustible products. It may be necessary to protect the wall
and materials around the stove. The unit has to rest on a solid, non-inflammable foundation. The flue
has to be tight, and its walls smooth; before connection, it should be cleaned of soot and all impuri-
ties. The connection between the flue and the unit has to be tight and made from non- inflammable
materials and protected against oxidisation (enamel or steel flue pipe). If the flue produces weak
draught, a new piping system should be considered. It is also important that the flue do not produce
excessive draught; a draught stabiliser should then be installed in the flue. Alternatively, special flue
endings can also be used to control the strength of draught. You should have the flue pipe checked
by a master chimney sweep, and modifications, if any, should be made by an authorised company so
as to ensure compliance with PN-89/B-10425.
Flue connection examples
Cleanout
Flue connection diameter
The freestanding stove should be placed on a non-inflammable foundation with a sufficient load-
carrying capacity. If the foundation is not suitable for supporting the stove's weight, appropriate
steps have to be taken to improve the load-carrying capacity of the foundation (e.g. use plates that
distribute the load across a larger area). The freestanding stove should be connected to a self-depen-
dent (exhaust gas) flue. The freestanding stove uses air for its operation, therefore it is necessary to
ensure proper ventilation in the room where the unit is installed. The inlet gratings of the ventilation
system should be protected against spontaneous closing.
2
Flue
Non-inflamma-
ble material
Grout
Rosette