Télécharger Imprimer la page

CLAS PE 6000T Mode D'emploi page 41

Publicité

Les langues disponibles

Les langues disponibles

PE 6001
PE 6000T
MOBILE SCISSOR LIFT DUAL CYLINDER LOW RAISE 3T
MOVABLE ELECTRO HYDRAULIC LIFT
Avoid operating in the machine's operating area if the hydraulic system is not fully equipped
with oil. When moving the platform, you have to adjust the space between the two bases
and make sure that the two bases are parallel.
CONNECTION OF THE ELECTRICAL LINE:
Connect the electrical and hydraulic connections according to the diagrams in this manual.
Connect the electrical and hydraulic connections according to the diagrams in this manual.
When connecting the oil pipes, pay particular attention to the protection in the pipe joint
to prevent foreign elements from entering the circuit and damaging the hydraulic system.
CONNECTIONS OF THE ELECTRICAL CIRCUIT:
Follow the path indicated in the «electrical diagram» to connect the electrical circuit.
Only competent personnel are authorized to perform this type of operation
Open the front cover of the control box.
Connect the power supply: the 3-phase power cables, 5-pole 400V (5 × 2.5mm cable)
have to be connected to the control box at the marked terminal.
The PE ground cable must first be connected to the marked terminal (image 15) and
then to the connections of the 2 bases.
If the lift is operated at 230V three-phase, a different electrical diagram must be used
which must be requested
to the manufacturer.
image 13
41
41

Publicité

loading