6
MODEL
EN
UPTN1
WARNING!
!
connected for use must be placed a minimum of 60" away from the appliance. Properly locate the
gas hose out of pathways where people may trip, and where the it will not be subject to accidental
damage.
48"
(1220 mm)
THE TABLE IS APPROVED FOR USE ON COMBUSTIBLE FLOORS.
!
WARNING!
adjacent combustibles are met.
www.napoleon.com
INPUT
FUEL
MAX. INPUT Btu/Hr
Propane Gas
50, 000
Never set an LP gas cylinder on top of the appliance enclosure. An LP gas cylinder
CENTRE OF PATIOFLAME
(610mm)
MAXIMUM
OVERHANG
72"
(1830mm)
EDGE OF
BURNER
It is important when selecting a location for your appliance to ensure clearances to
MINIMUM CLEARANCE TO COMBUSTIBLES
Side Walls
Top of unit to ceiling
GAS INLET PRESSURE RANGE
24"
INCHES
MM
48
1220
72
1830
PROPANE
Minimum
8" W.C.
Maximum
13" W.C.
60"
(1524 mm)
N415-0546 MAR 09.20