Instruction manual
The unit
The doors or windows
doesn't
are not closed.
cool
There are heat
enough.
sources inside the
room.
Hot air exhaust hose
is not connected or
blocked.
Temperature setting is
too high.
Air inlet in blocked.
Auto
Heating protection,
Power-Off
when the temperature
in heating
at the air outlet
mode.
exceeds 70 degrees,
the unit will power off
automatically.
Noisy.
The ground is not
level or not flat
enough.
The sound comes
from the flowing of the
refrigerant inside the
air conditioner.
E0 Code. •
Room temperature
sensor failed.
E2 Code. •
Water tank full
12
Make sure all the
windows and doors are
closed.
Remove the heat sources
if possible.
Connect or clean the hot
air exhaust hose.
Reset the temperature.
Clean the air inlet.
Allow room temperature
to cool before re-starting
the unit.
Place unit on a flat, level
ground if possible.
Replace room
temperature sensor.
Please empty the water
tank.
TABLE ED-7015
Information requirements for single
and double duct air conditioners
Information to identify the model(s) to
which the information relates to:
Description
Rated capacity for cooling
Rated capacity for heating
Rated power input for cooling
Rated power input for heating
Standby mode power consumption
OFF mode power consumption
Crankcase heater mode power
consumption
Information to identify the model(s) to which the information relates
to:
Description
Rated Energy efficiency ratio
Rated Coefficient of performance
Electricity consumption of single/
double duct appliances (indicate for
cooling and heating seperately)
Electricity consumption of double
ducts appliance
P
Symbol
Value
Unit
Prated
3.0
kW
Prated
N/A
kW
Peer
1.149
kW
Pcop
N/A
kW
EERd
0.5
W
Poff
N/A
W
Pck
N/A
W
Symbol
Value
Unit
EERrated
2.60
COPrated
N/A
Qsd
SD: 1.149
kWh/
(Cooling)
h
Qdd
N/A
kWh/
h