INSTALLATION INSTRUCTIONS
E-WFG SMALL Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This Product Must Be Installed In Accordance With The
Applicable Installation Code By A Person Familiar With
The Construction And Operation Of The Product And
The Hazards Involved.
Ce Produit Doit Être Installé Selon Le Code D'installation
Pertinent, Par Une Personne Qui Connaît Bien Le
Produit Et Son Fonctionnement Ainsi Que Les Risques
Inhérents.
3.
Min. 75°C supply conductors.
Les fils d'alimentation 75°C min.
4.
Suitable for wet locations.
Convient aux emplacements mouilles.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Fixture is designed for use with 4" octagonal or 4" square junction
boxes.
1. Remove the rear mounting plate by loosening the two Allen head set
screws from the bottom of the plate using the supplied wrench.
2. Pull supply leads from junction box through center hole in mounting
plate.
3. Fasten the mounting plate to the recessed junction box using
hardware supplied by others. The arrow on mounting plate should
be pointed up. Use the integrated bubble level to ensure the plate is
level.
following:
www.e-conolight.com
Document:
LPN00589X0001A0_A
Created By:
TMT
4. Make wiring connections per the Electrical Connections section.
5. Push the splices into the junction box.
6. Slide the fixture down over the upper edge of the mounting plate,
engaging the bracket on back of the housing with the upper edge
of the mounting plate. Retighten the set screws to hold the fixture in
place.
NOTE: To ensure a water tight seal, caulk between the rear housing
and the mounting surface.
WALL MOUNTED WITH CONDUIT FEED
1. Remove the rear mounting plate by loosening the two Allen head set
screws from the bottom of the plate using the supplied wrench.
2. Attach the mounting plate to the mounting surface using hardware
supplied by others. The arrow on mounting plate should be pointed
up. Use the integrated bubble level to ensure the plate is level.
3. Remove lens assembly by loosening screws on side of frame. Swing
lens assembly open,disconnect quick connect wiring connector(s)
and lift lens assembly upward to remove from housing.
4. From inside of the housing, pull the black, white, and green fixture
lead wires through the plug in the back of the fixture housing.
5. Seal the (3) holes in the plug in the back of the housing with a high
grade caulking material such as silicone rubber.
6. Slide the fixture down over the upper edge of the mounting plate,
engaging the bracket on the back of the housing with the upper edge
of the mounting plate.
7. Retighten the (2) set screws to hold the fixture in place.
8. Remove the appropriate plug(s) from the sides or top of the fixture
and attach surface conduit to the housing.
NOTE: Use of teflon tape on the conduit threads will ensure a
watertight seal.
9. Feed the supply leads through the conduit and into the fixture
housing.
10. Make wiring connections per the Electrical Connections section.
11. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 3.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
|
888.243.9445
|
FAX: 262.504.5409
Date
2018-05-08
ECO#
009170