● Ensure the unit is far away from fire, inflammable, or explosive
objects.
● The unit shall be installed in accordance with national wiring
regulations.
● Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
● The appliance shall be stored in a room without continuously
operation sources (for example: open flames, an operating gas
appliance or an operating electric heater).
● The appliance shall be stored so as to prevent mechanical damage
from occurring.
● Do not piece or burn, even after use.
● Be aware that refrigerants may not contain an odor.
● Pipe-work shall be protected from physical damage and shall not be
installed in an unventilated space, if that space is smaller than
4 m²/43sq.ft.
● Compliance with national gas regulations shall be observed. Keep
any required ventilation openings clear of obstruction. The appliance
shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
Any person who is involved with working on or
breaking into a refrigerant circuit should hold a current
valid certificate from an industry-accredited
assessment authority, which authorizes their
WARNING
competence to handle refrigerants safely in
accordance with an industry, recognized assessment
specification.
Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall
WARNING
be carried out under the supervision of the person
competent in the use of flammable refrigerants.
06
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the followings when
servicing an appliance with R32.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimized. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to
minimize the risk of a flammable gas or vapor being present while the
work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined
spaces shall be avoided. The area around the work space shall be
sectioned off. Ensure that the conditions within the area have been
made safe by control of flammable material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially flammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with flammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate fire extinguishing equipment shall
be available to hand. Have a dry powder or CO2 fire extinguisher
adjacent to the charging area.
07