MACHINE STORAGE
If you don't use the unit for an extended period of time, please
store it per the following steps:
(1) Clean the filter mesh.
(2) ATTENTION: The evaporator inside the machine has to be dried
out before the unit is packed to avoid component damage and molds.
Unplug the unit and place it in a dry open area for days to dry it out.
Another way to dry the unit is to set the humidity point more than 2%
higher than the ambient humidity to force the fan to dry the evaporator
for a couple of hours.
(3) Store the power cord pocket at the back of unit.
(4) Store in a clean, dry environment.
TROUBLE SHOOTING
Trouble
Cause
Unit is not
Machine
plugged in.
does not run
Room temperature
under 41
100.4
F.
o
Machine runs
When the humidity set
butdoes not
point is 2% higher than
dehumidify
ambient humidity.
20
Solution
Plug in the unit.
To protect the machine,
F or above
o
use it only when the
ambient temperature is
between 41
F and
o
100.4
F.
o
Reset the humidity to
a lower set point, or
power off the machine
if the humidity has
satisfied you.
Filter mesh jammed.
Reduce
dehumidifier
capacity
Air-in and/or Air-out
louvers jammed.
No air inlet
Filter mesh or air-in
louver jammed.
Machine situated on an
incline or decline slope.
Loud Operation
Filter mesh jammed.
Cautions: Switch off the unit and unplug it immediately if anything
abnormal happens. Then contact qualified personnel.
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities.
Contact your local regulation for information regarding the
collection systems available.
Clean the filter mesh
according to manual.
Clear the blockage
from Air-in and/or
Air-out louvers.
Clean filter according to
instructions or clean the
louver blockage.
Move to flat ground.
Clean filter mesh
according to
instructions.
21