The meaning of the error code on the screen and how to deal with it
Code
F1
Low battery protection
F2
Fan overload protection
Compressor start - Frequently
F3
protection
The compressor speed is too
F4
low or the load is too large
Control module overheat
F5
protection
F6
Controller hardware failure
Temperature head short
F7
circuit
F8
Temperature head open
Cleaning
Before cleaning, remove the products from the device and remove the plug from the power supply. Only clean
with a slightly damp cloth, if necessary a non-aggressive cleaning agent can be used. After cleaning, always dry
all wet surfaces with a dry cloth.
Never use sharp or abrasive products to clean the device.
Defrost the cool box: frost can settle on the evaporator or inside of the cool box due to humidity, this can reduce
the cooling capacity. The cool box must be defrosted in time. As follows
Take the products out of the cool box
Switch off the device
Open the lid
Sweep up the melt water or drain the melt water through the plug.
Recycling
This product bears the selective sorting symbol for waste electrical and electronic equipment This means
that this product must be handled pursuant to European Directive (2012/19/EU) in order to be recycled or
dismantled to minimize its impact on the environment. For further information, please contact your local
or regional authorities. Electronic products not included in the selective sorting process are potentially
dangerous for the environment and human heath due to the presence of hazardous substances.
Declaration of conformity
Hereby Gimeg Nederland B.V. declares that the device MCC-35, applies all basic requirements and other relevant
regulations listed in the European directive for electromagnetic compatibility (2014/30/EU) and low voltage directive
(2014/35/EU). If you require a full declaration of conformity, you can contact the adress listed on the backside of this
manual
Technical product information
Product name
Volume
Climate classification
Refrigerant quantity
Foam vesicant
Net weight
Main voltage
Rated current
Rated power
Consumption of energy
Type of error
Charge the battery or lower the battery protection position
Turn off the power for 30 minutes and then restart. If it appears agaian, please
contact the after sales staff
Turn off the power for 30 minutes and then restart. If it appears agaian, please
contact the after sales staff
Turn off the power for 30 minutes and then restart. If it appears agaian, please
contact the after sales staff
Place the cool box in a well-ventilated place, turn it off for 30 minutes, and then
restart it. If it appears again, please contact the after-sales staff
Shut down and restart; if it appears again, please contact the after sales staff
Place the cool box in a well-ventilated place, turn it off for 30 minutes, and then
restart it. If it appears again, please contact the after-sales staff
Place the cool box in a well-ventilated place, turn it off for 30 minutes, and then
restart it. If it appears again, please contact the after-sales staff
MCC-35
35L
SN, N, ST, T
R1234yf (24g)
C5H10
15 kg
12 V / 24 V (DC), 100-240 V (AC)
5 A/2.5 A (0,24 kWh/24h) (DC), 1.2 A - 0.5 A (AC)
60 W
0,24 kWh/24h