14 Technical Data
14.1 PKS 10 AF 1
Specification
Output function
Temperature range
Angle of aperture
Spot size
Focusing distance
Current carrying capacity
Power requirement
Protection class
Insulation voltage
Short-circuit proof
Reverse voltage protection
Overload-proof
Voltage drop
Current consumption
Response time
Spectral sensitivity
Hysteresis
Measuring uncertainty
Permissible humidity
Ambient operating temp.
Storage temperature
Protection rating
EMC
Housing material
Lens material
Function display of
switching statuses
Connectivity
Operating controls
Display
Operating parameters
Ø 12 mm at focusing distance
150 mA per output (definite time-delay overcurrent protection ≥ 250 mA)
50 V DC Pin 1 to 5, to the housing
≤ 2,5 V for I
≤ 150 mA per switching contact
L
≤ 30 mA at 24 V DC without load current
Upper + lower thresholds configurable via control keys
(at ε =1.0 and T A = 23 °C)
95 % r.H. max. (non-condensing )
IP 65 (IP65 connecting cable attached)
EN 61000-6-4: EN 55011(30 – 1000MHz)
EN 61000-6-2: EN 61000-4-2 / -3 / -4 / -6
with shielded cable
Shield must be connected to device housing!
IR transmissive crystal lens, antireflection-coated
Connector: M12 plug connector 5-pin A-coded
2 x 7-segment red LEDs (digit height 8 mm)
Measurement value is a percentage relative to the temp. range
Switching point as % of span; upper and lower threshold values;
switching function of contacts (N/O, N/C)
25
Operating manual PKS
Model PKS 10
N/O contact PNP
50 – 500 °C
adjustable
2.3 °
300 mm
10 – 34 V DC
III
yes
yes
yes
≤ 100 ms
8 – 14 µm
1 % of full scale
0 – 65 °C
-20 – 80 °C
Stainless steel
2 x yellow LEDs
3 control keys