Please read the instructions carefully before use.
1 Production introduction
• D_HEATER is suitable for heating resin, Branscan agar, sodium hypochlorite. Adopting preci-
se circuit control and imported heating tube, it can set any integer temperature within 40 -70ºC
according to the heating object.
• Some materials and recommended temperature.
No.
Material
1
Resin(for filling)
2
Resin (for bonding)
3
Branscan
4
Agar film
5
Sodium hypochlorite
2 Structure
1- ON/OFF/SET
2- Increase key
3- Decrease key
4- DC
5- 60mm heating hole
6- 70mm heating hole
3 State/Mode description
• Standby state:screen display"--ºC"
• Heating mode: the number area is always on, the temperature symbol is flashing. After rea-
ching the system preset temperature or D_HEATER temperature is higher than the system
preset temperature: the number area is always on, and the temperature symbol always on.
• Mode setting: the number area is always on, "S" flashing.
4 Instructions
• After plug the power supply, the digital tube is always on"-- ºC"
• After plug the power supply,single press "ON/OFF/SET". D_HEATER goes into the heating
state according to the set temperature at previous power-off. It automatically stops heating
after reaching preset temperature.
• After plug the power supply, single press "+" or "-" into the setup mode. Press "+" can increa-
se the preset temperature. Press "-" can decrease the preset temperature. After setting, sin-
gle press "ON/OFF/SET" into the heating state. It automatically stops heating after reaching
4
1
3
6
7- Heating base
8- Support leg
9- Display screen
10- Temperature display
11- Temperature/Heating signal "ºC"
12- Setting signal "S"
5
10
7
9
8
Recommended temperature (ºC)
39
55
38
Melting 99; Insulation 60
60
11
12