PROGRAMMING
T-SERIES
BUFFER VPD SETTING
The buffer figure will create a trigger-off point
below your set trigger point to prevent your
device from shutting off too quickly. Press
the up or down button to cycle through buffer
range from 0.1 kPa and 1.0 kPa.
In high VPD triggers, your device will turn on,
only turning off when the VPD falls below your
buffer setting.
In low VPD triggers, your device will turn on,
only turning off when the VPD rises above
your set buffer setting.
EXAMPLE
In this example, your High VPD Trigger is set
at 2.51 kPa and your VPD Buffer is set at 0.2
kPa. Your device will trigger on when it meets
or rises above 2.51 kPa, and only trigger off
when it falls below 2.31 kPa%. The 2.51 kPa
figure is obtained by taking your High VPD
Trigger of 2.51% and subtracting your VPD
Buffer of 0.2 kPa.
56
BUFF.
This setting will only appear in ports
connected with outlet adapters.
2.31
kPa
2.51
kPa