6. INTRODUCTION
The GE 21-1A is a new-generation portable electric inflator with high efficiency, synonymous
reliability and functionality. The GE 21-1A is equipped with a double-piston pumping unit which
allows any object to be inflated to a pressure of between 10 and 1500 mbar. The inflator starts
when the ON button is pressed and switches off automatically when it reaches the set pressure on
the pressure gauge. When the user presses the OFF button, the device stops. The GE 21-1A is fully
portable as the battery is integrated in the apparatus. When the battery is low (red light on the
manometer), the inflator can be connected to a 12V cigarette lighter socket or 110-240 AC/DC
transformers.
The inlet port is protected by a multilayer filter, the outlet port is equipped with a non-return valve.
The unit is protected against overheating. In the event of high outside temperature or overuse, the
inflator will automatically stop and a red LED on the pressure gauge will indicate the status. When
the red LED goes out, the unit can be restarted.
7.RECOMMENDED USES
Inflatable items, such as: SUPs / Small rubber dinghies (3/4 m) / Kayak / Kites / Rafts / Air
mattresses / Swimming pool floats / etc.
8. TECHNICAL SPECIFICATIONS
SAFETY FUSE
MAX. PRESSURE
FLOW RATE
ITEM
FUNCTIONS
(mbar)
(L / minute)
GE 21-1A
125
30 A
1,500 (22 PSI)
INFLATION
PRESSURE SETTINGS: PRESSURE GAUGE WITH AUTOMATIC SWITCHING OFF
INFLATION FITTINGS: AVAILABLE FOR MOST COMMON VALVES
CARRY BAG DIMENSIONS: 220x320x220 mm
9. USE FOR INFLATING
ACCESSORIES AND POWER CABLES
1. The 12V cable and the fitting bag are located inside carry bag upper compartment.
2. The inflation hose is located inside the box, outside the carry bag.
3. The battery charger and the fuse are located inside carry bag lower compartment.
CONNECTING THE ACCESSORIES
1. The inflator is supplied with standard conical adapters that are located inside carry bag upper
compartment.
2. Make sure that the OFF button has been pressed.
3. Take the hose from the carry bag.
4. Connect the air hose to the port to inflate (OUT).
5. Assemble the most suitable adapter for the inflator
TURNING ON THE INFLATOR
1. To INFLATE, connect the hose to the outlet port (N5 fig. on p.3).
2. Set the desired pressure on the pressure switch (N1 fig. on p.3).
3. The device starts when the ON button is pressed.
The inflator will automatically stop when the set pressure is reached.
CORRECTLY CONNECT THE HOSE TO THE INFLATOR AND THE INFLATABLE, ENSURING THAT
THERE ARE NO LEAKS. CHOOSE THE APPROPRIATE GASKET FROM THOSE SUPPLIED.