SAFETY INSTRUCTIONS
Read the instructions carefully before use.
•
There are no replaceable components inside
the smoke detector. Only the battery is
replaceable.
•
Do not use the product in humid, dusty or
smoky environments.
•
When the battery capacity reaches a low level
the smoke detector will emit an audio prompt
approximately every 45 seconds to indicate that
the battery needs to be replaced.
•
Store the smoke detector and packaging
materials out of the reach of children.
SYMBOLS
Read the instructions.
Approved in accordance with the
relevant directives.
Recycle discarded product in
accordance with local regulations.
TECHNICAL DATA
Power source
Current consumption in standby
Operating temperature
Sound level for alarm
Size
Standard
HOW TO USE
The smoke detector functions through the dispersal
of infrared radiation in the smoke that develops
in the initial phase of the fire. It consists of a
photoelectric system that processes the signals from
the infrared radiation. The infrared radiation spreads
out over the surface of the smoke when the smoke
comes in the smoke detector. The photoelectric diode
receives the dispersed radiation and activates the
photoelectric current, which starts the alarm signal.
1.
2.
3.
1.
2.
3.
9 V battery
4.
6–12 uA
-10°C to +40°C
≥ 85 dB/3 m
101 × 34 mm
EN 14604
INSTALLATION
Remove the mounting plate on the back of the
smoke detector and insert a 9 V battery.
FIG. 1
Press the test button for a few seconds to start
the alarm. Release the button when you hear
the alarm (it sounds two or three times and
then stops automatically). This shows that the
smoke detector is working.
FIG. 2
Install the smoke detector in a suitable place
with the two supplied screws (e.g. one the
ceiling).
1. Screws
2. Mounting plate
FIG. 3
REPLACING THE BATTERY
Grip the smoke detector casing, twist
anticlockwise and unhook the detector from
the wall/ceiling holder.
Remove the old battery and then connect the
new battery.
Put the new battery in the battery
compartment, fit the detector in the wall/
ceiling holder and lock in place in the holder by
twisting clockwise.
Test the smoke detector by pressing the test
button. The alarm gives a loud audio prompt.
If there is no load alarm signal the smoke
detector is either defective or incorrectly
installed. See troubleshooting section.
OBS!
•
The detector will not fit in the wall/ceiling
holder if no battery is inserted.
•
Do not take out the battery unless a new
battery is to be immediately inserted.
EN
7