Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Trusted. Tested. Tough.
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
2057 pump powered by
Zoeller Motor Works motor
2000 SERIES HIGH TEMPERATURE INTERMITTENT PUMPS
SERIES
2057
2098
2137
2282
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1.
Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover nor the
motor housing.
2.
Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
1. Make sure there is a properly grounded receptacle available. All pumps are furnished
with provisions for proper grounding to protect you against the possibility of electrical
shock.
2. Make certain that the receptacle is within reach of the pump's power supply cord. DO NOT
USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor, and they could present a safety hazard if the insulation
were to become damaged or the connection end were to fall into a wet or damp area.
3. Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers
of proper capacity. A separate branch circuit is recommended, sized according to the
"National Electrical Code", for the current shown on the pump nameplate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked for
ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the
power, neutral and ground wires are correctly connected to your outlet. If they are not,
call a qualified, licensed electrician.
5. For Added Safety. Pumping and other equipment with a 3-prong grounded plug must be
connected to a 3-prong grounded receptacle. For added safety, the receptacle may be
protected with a ground-fault circuit interrupter. When a pump needs to be connected in
a watertight junction box, the plug can be removed and spliced to the supply cable with
proper grounding. For added safety, this circuit may be protected by a ground-fault circuit
interrupter. The complete installation must comply with the National Electrical Code and
all applicable local codes and ordinances.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE
HANDLING. Single phase pumps are supplied with a 3-prong grounded plug to help protect
you against the possibility of electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong
grounded receptacle. If the installation does not have such a receptacle, it must be changed
to the proper type, wired and grounded in accordance with the National Electrical Code
and all applicable local codes and ordinances. Three phase pumps require motor starting
devices with motor overload protection. See FM1596 for simplex installations or FM0486 for
duplex installations. Pumps must be installed in accordance with the National Electrical Code
and all applicable local codes and ordinances. Pumps are not to be installed in locations
classified as hazardous in accordance with National Electrical Code, ANSI/NFPA 70.
7. Risk of electrical shock. Do not remove power supply cord and strain relief or connect
conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should be performed by a
qualified, licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electric shock. These pumps have not been investigated for use in swimming pool
areas.
11. Prop65 Warning for California residents:
: Cancer and Reproductive Harm-
www.P65Warning.ca.gov.
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
Tel: (502) 778-2731 • 1 (800) 928-PUMP
INSTALLATION INSTRUCTIONS
AVAILABLE MODELS
HP
DISCHARGE
1/3
1-1/2"
1/2
1-1/2"
1/2
1-1/2"
1/2
2" or 3"
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2023 Zoeller
SOLIDS
PH
1/2" (13 mm)
1
1/2" (13 mm)
1
5/8" (16 mm)
1
2" (50 mm)
1
CAUTION
1. Check to be certain your power source is capable of handling the voltage requirements of
the motor, as indicated on the pump name plate.
2. Check valves used in High Temperature service must be all metal swing type check valves.
3. Dewatering and effluent sump pumps are not designed to handle raw sewage.
4. Maximum intermittent operating temperature for high temperature pumps must not exceed
200 °F (93 °C).
5. The installation of automatic pumps with variable level float switches or nonautomatic pumps
using auxiliary variable level float switches is the responsibility of the installing party and
care should be taken that the tethered float switch will not hang up on the pump apparatus
or pit peculiarities and is secured so that the pump will shut off. It is recommended to use
rigid piping and fittings and the pit be 18" (46 cm) or larger in diameter.
6. Vent hole. It is necessary that all submersible sump, effluent, and sewage pumps capable
of handling various sizes of solid waste be of the bottom intake design to reduce clogging
and seal failures. If a check valve is incorporated in the installation, a
must be drilled in the discharge pipe below the check valve and pit cover to purge the unit
of trapped air. Trapped air is caused by agitation and/or a dry basin. Vent hole should be
checked periodically for clogging. The 50 or 90 Series pumps have a vent located in the
pump housing opposite the float, adjacent to a housing lug, but an additional vent hole is
recommended. The vent hole on some applications may cause too much turbulence. If you
choose not to drill a vent hole, be sure the pump case and impeller is covered with liquid
before connecting the pipe to the check valve and no inlet carries air to the pump intake.
NOTE: THE HOLE MUST ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY.
Water stream will be visible from this hole during pump run periods.
7. Pump should be checked frequently for debris and/or build up which may interfere with
the float "on" or "off" position. Repair and service should be performed by Zoeller Pump
Company Authorized Service Station only.
8. Do not operate a pump in an application where the Total Dynamic Head is less than the
minimum Total Dynamic Head listed on the Pump Performance Curves.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
Supersedes
Visit our website:
zoellerpumps.com
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
MATERIAL
Cast iron / Stainless steel
Cast iron / Stainless steel
Cast iron / Stainless steel
Cast iron / Stainless steel
SEE BELOW FOR
LIST OF CAUTIONS
/
" (5 mm) vent hole
3
16
FM1923
0823
1222

Publicité

loading

Sommaire des Matières pour Zoeller 2000 Serie

  • Page 1 Three phase pumps require motor starting the float “on” or “off” position. Repair and service should be performed by Zoeller Pump devices with motor overload protection. See FM1596 for simplex installations or FM0486 for Company Authorized Service Station only.
  • Page 2 • Not to be used with flammable liquids. • Not meant for use in hazardous locations as defined by the National Electric Code and ANSI/NFPA 70. • Switch is not designed to be directly wired to power source © Copyright 2023 Zoeller Co. All rights reserved. ®...
  • Page 3 IMPORTANT! **SECURE THE PUMP POWER CORD TO LEVEL LENGTH CANNOT BE THE DISCHARGE PIPE AS SHOWN IN FIGURE 2.2. CORD LESS THAN 4" (10 CM). SHOULD BE AT OR ABOVE THE PUMP “ON” LEVEL. SK2067B © Copyright 2023 Zoeller Co. All rights reserved. ®...
  • Page 4 If the above check list does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must be by Zoeller Authorized Service Stations. © Copyright 2023 Zoeller Co. All rights reserved.
  • Page 5 La reparación y servicio deberá hacerse solamente por personal de una estación 7. Riesgo de descarga eléctrica. No quite el cable de alimentación eléctrica ni el dispositivo de servicio autorizada por Zoeller Pump Company. de alivio de tensión y no conecte un conductor directamente a la bomba.
  • Page 6 • No está diseñado para su uso en lugares peligrosos según se definen en el Código Eléctrico Nacional y ANSI / NFPA 70. • El interruptor no está diseñado para ser conectado directamente a una fuente de alimentación © Copyright 2023 Zoeller Co. Todos los derechos reservados.
  • Page 7 LONGITUD DE SUJECIÓN NO MUESTRA EN LA FIGURA 2.2. EL CABLE DEBERÍA UBICARSE PUEDE SER INFERIOR A 10.2 EN O POR ENCIMA DEL NIVEL DE ENCENDIDO DE LA BOMBA. CM (4 PULG.). SK2067B © Copyright 20232 Zoeller Co. Todos los derechos reservados. ®...
  • Page 8 Si la lista de verificación arriba mencionada no revela el problema, consulte con el departamento de Product Support. No intente proporcionar algún servicio o desarmar la bomba. Las estaciones de servicio autorizadas por Zoeller deberán proporcionar dicho servicio. © Copyright 2023 Zoeller Co.
  • Page 9 / arrêt. Les réparations ne doivent être faites que par un centre de réparation agréé par Zoeller Pump Company. 8. L’installation et la vérification de l’équipement électrique doivent être faites par un électricien qualifié.
  • Page 10 • Ne pas utiliser dans des emplacements dangereux tels que définis par le Code national d’électricité américainet la norme ANSI/NFPA 70. • L'interrupteur n'est pas conçu pour être raccordé directement à une source d'alimentation. © Copyright 2023 Zoeller Co. Tous droits réservés.
  • Page 11 INFÉRIEURE À 10,2 CM (4 PO) D’ÉVACUATION COMME INDIQUÉ À LA FIGURE 2.2. LE CORDON DOIT SE SITUER AU NIVEAU OU AU-DESSUS DU NIVEAU « MARCHE » DE LA POMPE SK2067B © Copyright 2023 Zoeller Co. Tous droits réservés. ®...
  • Page 12 Inspecter la conduite. Déposer la base et inspecter. Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les réparations doivent être faites par un centre de réparation agréé par Zoeller. © Copyright 2023 Zoeller Co.

Ce manuel est également adapté pour:

Bn2057Bn2137Bn2098228220572098 ... Afficher tout