Max. output continuous
current [a.c.A]
Nominal AC voltage [a.c.V]/
Grid range
Nominal grid frequency [Hz]
Displacement power factor
ITHDi (rated power) [%]
Nominal AC Voltage [a.c.V]
Current (inrush) [a.c.A]
Maximum output fault current [a.c.A]
Maximum output overcurrent
protection [a.c.A]
Note:
1. 4048 (3680 for G98, TOR and PPDS)
3. 17.4 (16 for G98)
5. 5000 (4600 for VDE4105; 4999 for AS4777.2)
7. 5000 (4600 for VDE4105; 4999 for AS4777.2)
9. 26.1 (25 for EN50549_Ireland)
• System Data, Protection and Standard
Model
Max. efficiency [%]
Euro. efficiency [%]
Standby consumption
[W] @Night
Ingress protection
Protective class
Overvoltage category
Operating ambient temperature
range [°C]
Max. operation altitude [m]
Humidity [%]
Typical noise emission [dB]
Storage temperature [°C]
Dimensions(W×H×D) [mm]
Weight [kg]
Cooling concept
Communication interfaces
Optional monitoring dongle
Over/under voltage protection
DC isolation protection
Monitoring ground fault protection
Grid monitoring
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
Over temperature protection
SPD (PV/AC)
AFCI
Safety
EMC
Grid monotoring
Inverter typology
Active anti-islanding method
Micro-breaker
Note:
1. For models with internal fan (optional), typical noise emission is 30 dB.
17.4⁴
2. 17.6 (16 for G98, TOR and PPDS)
4. 17.4 (16 for G98)
6. 21.7 (20 for VDE4105)
8. 21.7 (20 for VDE4105)
X1-BOOST-
X1-BOOST-3K-G4
2.5K-G4
98
97
11
RS485/DRM/USB/Heat Pump, Optional: CT/Meter
EN61000-6-1/2/3/4;EN61000-3-2/3/11/12
IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105,
20.1
21.7
220/230/240; 90-290
50/60; ±5
0.8leading-0.8lagging
<3
220/230/240
50
58 (15 ms)
35
X1-BOOST-
3.3K-G4
98
98
97
97
3
IP66
I
II (DC), III (AC)
-25-60
4000
0-100
1
25
-30-70
404x274x146
11
11
Nature cooling
Pocket WiFi/LAN/4G
YES
YES
YES
YES
YES
YES
YES
YES
YES
II/II
Optional
EN/IEC62109-1/2
CEI 0-21, VFR, PPDS, TOR
Non-isolated
Frequency shift
20A
8
27.3
X1-BOOST-
3.6K-G4
98
97
11