5.3 Regulating the reduced capacity (Fig. 5)
Unscrew the screw "F" of the minimum and turn it until the reduced capacity indicated in
table 2 is obtained. Check that the quantity of gas is sufficient for maintaining a stable and
even minimum and for resisting the change from maximum to minimum capacity.
5.4 Replacing the oven injector
Remove the base of the oven.
5.4.1 Pilot flame (Fig. 7)
If the pilot flame has been regulated correctly it should envelop the thermocouple and have a
perfect exterior appearance. If this is not the case, unscrew the screw "G" and check that the
injectors installed are the right ones (see tables 3).
5.4.2 Main burner (Fig. 8)
Unscrew the injector "I" and mount the one foreseen with a 12 mm spanner.
6. ACCESSIBILITY AND DISASSEMBLY OF THE PARTS
(only for qualified installers)
6.1 Oven gas valve
• Unscrew the two attachment screws and remove the front right-hand panel, disengaging the attachment pins.
• Unscrew the nuts of the gas pipes and that of the thermocouple, remove the temperature sensor from its position inside the
oven chamber and disconnect the wire of the piezoelectric lighting device.
• Using a spanner, unscrew the two screws which attach the gas valve.
• Mount the new valve.
6.2 Gas cock of the hob burners
• Disengage the 4 pins which attach the control panel and remove it.
• Unscrew the nuts of the gas pipes and that of the thermocouple and those which attach the gas cock to the gas ramp.
• Mount the new gas cock.
6.3 Oven igniter plug
• Remove the base of the oven.
• Unscrew the attachment nuts of the igniter plug.
• Remove the plug.
• Disconnect the igniter plug wire.
• Mount the new plug..
6.4 Electric oven
The resistors are positioned in the ceiling (higher heat) and under the chamber (lower heat). The temperature is regulated
between 50 and 280¡C by means of two thermostats which control the resistors independently. In order to light the oven and
regulate the temperature turn the knob of the thermostat to the required temperature setting.
CAUTION: Before starting maintenance work, remove the pilot light or disconnect the switch placed upstream.
A safety thermostat can turn out the higher resistor (in the ceiling) in the event of malfunctioning. In the event of faulty working
switch the appliance off and call the service centre.
• OPERATION
The pilot light "S" lights, indicating that power is supplied to the appliance.
Turn the thermostat "U" to the required temperature.
The pilot light "T" lights, indicating that the resistors are on; as soon as the required
temperature is reached it goes out. When the resistors are newly actuated it lights again.
In order to switch off the appliance turn the knobs to the initial setting.
7. OPERATING INSTRUCTIONS
Caution: before using the appliance the plate has to be cleaned with hot water and detergent.
(Fig. 5)
(Fig. 8)
F
(Fig. 7)
S
T
U
110
280
130
255
150
230
170
210
190