10.5 HELP IN CASE OF MALFUNCTION
Danger of electric shock
When working on the pump, there is the risk of receiving an electric shock.
- Disconnect the mains plug before correcting any malfunctions!
- Faults in the electrical system must be rectified by a qualified electrician.
Malfunction
Motor does not run.
Pump running but does not
feed.
Delivery rate too low.
Possible cause
Impeller blocked.
Thermal protection switch has
switched off.
No mains power.
Water level too low.
Air in pump housing.
Pump drawing in air.
Blockage on the suction side.
Pressure line closed off.
Pressure hose kinked.
Pressure hose kinked.
Hose diameter too small.
Blockage on the suction side.
Feed head to high.
Remedy
Remove dirt from the suction area.
Clean with a suitable tool through
the opening on the back of the motor
housing.
Wait until the thermal protection
switch on the pump switches on
again. Take note of the maximum
temperature of the conveying medi-
um. Have the pump inspected.
Check fuses, have the power supply
checked by a qualified electrician.
Submerge the suction hose deeper.
Fill the pump.
Check all connections and the cover
on the filter for leaks.
Caution!
Risk of burns from hot
water!
Remove dirt from the suction area.
Caution!
Risk of burns from hot
water!
Open the pressure lone.
Extend the pressure hose.
Extend the pressure hose.
Use a hose with a bigger diameter.
Remove dirt from the suction area.
Observe max. feed head, see tech-