Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30 mm. Please select
heat-resistant work surface material to avoid larger deformation caused
by the heat radiation from the hotplate. As shown below:
5cm mini
Under any circumstances, make sure the Induction cooker hob is well
ventilated and the air inlet and outlet are not blocked. Ensure the induction
cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least 760 mm.
Air intake
59cm
49cm
5cm mini
mini 760 mm
mini 5 cm
Air exit
mini 5 mm
mini 2 cm
Installation
5cm mini
- 5 -
52cm
56cm
5cm mini