Burner and nozzle specifications (for 75 cm versions only)
Table 1
Diameter
Burner
(mm)
Reduced Rapid (RR)
100
Semi Rapid (S)
75
Auxiliary (A)
55
Triple Crown (TC)
130
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
RR
S
TC
A
S
PKL 751 T/IX/A
All manuals and user guides at all-guides.com
Liquid Gas
By-pass
Thermal
Thermal
Power
Power
1/100
kW (p.c.s.*)
kW (p.c.s.*)
(mm)
Reduced
Nominal
0.70
2.60
39
0.40
1.65
28
0.40
1.00
28
1.50
3.30
61
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Nozzle
Flow*
Thermal
Power
1/100
g/h
kW (p.c.s.*)
(mm)
**
***
Nominal
80
189
186
2.60
64
120
118
1.65
50
73
71
1.00
65x2
240
236
3.60
28-30
37
20
25
35
45
GB
Natural Gas
Nozzle
Flow*
1/100
l/h
(mm)
122(H3)
248
96(Z)
157
79(6)
95
103x2
343
20
17
25
11

Publicité