Start-up
Danfoss RAV
Danfoss valve bodies have elongated
notches around their circumference,
which also ensure that the adapter is
properly seated when it snaps on.
During installation, please ensure
that the pins inside the adapter
are lined up with the notches on
the valve.
Snap the adapter complete-
ly onto the valve.
• Secure the adapter with the en-
closed screw and nut.
• Place the spigot extension on the
valve pin.
Figure 11
Danfoss RAVL
Danfoss valve bodies have elongated
notches around their circumference,
which also ensure that the adapter is
properly seated when it snaps on.
During installation, please ensure
that the pins inside the adapter
are lined up with the notches on
the valve.
• Snap the adapter completely onto
the valve.
• Place the spigot extension on the
valve pin.
The RAVL adapter does not need
to be screwed on.
Figure 12
6.3
Adjustment run
When the batteries are inserted,
the motor retracts to simplify
installation. Meanwhile, "
the activity symbol ( ) are dis-
played.
If the adjustment run was initiated
prior to installation, or if an error
message (F1, F2, F3) is displayed,
press the system button (D): the
motor will reverse to the "
tion. The adjustment run can then
be restarted.
After the radiator thermostat has been
mounted successfully, an adjustment
run (
) must be performed to adjust
MANU
BOOST
the device to the valve. To do this, pro-
C
ceed as follows:
• When "
" is shown in the display,
MANU
BOOST
press the system button (D) to start
C
the adjustment run.
If the display backlight is off, you
must press button (D) a second
time to start the adjustment run.
MANU
BOOST
" and
C
MANU
BOOST
" posi-
C
26