General information
¡ Read this instruction manual carefully.
¡ Only a licensed expert may connect the
appliance.
¡ Improper installation, opening of the appli-
ance, connection or assembly may lead
to a loss of validity of the product war-
ranty.
¡ Switch off the power supply before carry-
ing out any work.
¡ After installation, ensure that the user
does not have access to the electrical
components.
¡ Never use this appliance in boats or in
vehicles.
Safe installation
Follow these safety instructions when in-
stalling the appliance.
The appliance can only be used safely if it
is correctly installed in accordance with the
installation instructions. The installer is re-
sponsible for ensuring that the appliance
works perfectly at its installation location.
WARNING ‒ Danger: Magnetism!
The appliance contains permanent mag-
nets. They may affect electronic implants,
e.g. pacemakers or insulin pumps.
▶ Persons with electronic implants must
stand at least 10 cm away from the appli-
ance.
WARNING ‒ Risk of injury!
Parts that are accessible during installation
may have sharp edges and may lead to cut-
ting injuries.
▶ Wear protective gloves.
Chemicals may be dangerous. When hand-
ling chemicals, you must observe the re-
commendations of the chemical producers.
▶ Wear personal protective equipment.
Instructions for the electrical connection
In order to safely connect the appliance to the elec-
trical system, observe the following instructions.
¡ Only an authorised expert or a specially trained
service technician may connect the appliance. The
person must be approved in accordance with the
local regulations of the country and the electricity
supply company.
¡ Connect the appliance to a fixed installation and
set up appropriate isolating switches in accord-
ance with the installation regulations.
¡ The manufacturer shall assume no liability for mal-
functions or damage resulting from incorrect elec-
trical wiring.
Connection type
¡ The appliance corresponds to protection class 1.
You should therefore only use the appliance with
a protective earth connection.
Power cord
The power cord can be connected to the mains
socket for the hob or included with the appliance.
¡ You can find the required connection data on the
type plate and in the connection diagram.
¡ Use only the connection cable that is supplied
with the appliance or is supplied by customer ser-
vice. If you require a longer cable, contact cus-
tomer service. Connection cables up to 2.20 m
long are available.
Information on fitted units
¡ You can only install the induction hob above draw-
ers or ovens with fan ventilation. Do not install re-
frigerators, dishwashers, non-ventilated ovens or
washing machines below the hob.
¡ Ensure that the fitted unit is heat-resistant up to at
least 90 °C.
Worktop
Follow the worktop manufacturer's recommenda-
tions.
¡ Level, horizontal, stable.
¡ The worktop into which you are fitting the appli-
ance must be able to withstand loads of approx.
60 kg.
¡ For thin worktops, use heat-resistant and moisture-
resistant reinforcement material.
¡ Only check the evenness of the hob after it has
been installed.
Extractor hood
¡ The clearance between the extractor hood and the
hob must correspond at least to the clearance
specified in the installation instructions for the ex-
tractor hood.
Preparing the fitted units
Mark the unit cut-out in accordance with the in-
1.
stallation diagram.
Ensure that the angle of the cut surface to the
worktop is 90°.
→ Fig.
1
After making the cut-outs, remove any shavings.
2.
Seal the cut surfaces with heat-resistant material.
3.
Ventilation
To guarantee that the appliance works correctly, the
hob must be sufficiently ventilated. The ventilation in
the lower section of the appliance requires a suffi-
cient supply of fresh air. Therefore, if required, adjust
the units for this purpose.
Maintain a minimum clearance between the rear
1.
of the unit and the kitchen wall.
→ Fig.
2
Ensure that an opening at the top of the rear of
2.
the unit is unobstructed.
→ Fig.
3
If the clearance from the back wall of the unit is
3.
less than 20 mm, create an opening on the under-
side.
→ Fig.
4
If the inside of the unit is not wider than 780 mm,
4.
make cuts on the side panels.
→ Fig.
5
Do not hermetically seal the lower base.
5.
9