INSTALLATION
Ø150
H1
2x
Connections
Ducted version air exhaust system (AV361RVS)
When installing the ducted version, connect the hood to the chimney
using either a flexible or rigid pipe ø150 mm or 120 mm, the choice of
which is left to the installer.
• For ducted versions, use the supplied shut-off valves to prevent
backflow of air through the exhaust duct. Click these into the motor
outlet (see drawing).
• To install a ø150 mm air exhaust connection, insert the flange on
the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not supplied).