After installation and any fault, a complete check of the safety function must
be performed.
12.1 Teach-in variant "individual"
The first permitted actuator is detected immediately after the supply voltage is
applied, if it is located in the detection range of the sensor.
Each additional teach-in process must be done as described in the following:
1. Apply the supply voltage to the safety sensor.
2. Bring an allowable actuator into the detection range of the sensor.
3. Actuator is detected, red LED flashes six times.
4. After 10 s the LED switches to yellow flashing.
5. Switch off power supply within the next 2 min.
6. Re-apply power supply, the programming procedure is finished and the
actuator will be accepted.
7. If an actuator is re-taught, the safety sensor disables the code of the
previous process, so this is no longer permitted.
8. Do not remove the actuator during the process, as long as it is located in
the detection area.
If the teach-in procedure is terminated, the supply voltage must be switched
off and the process restarted. The teaching-in of actuators to a security sensor
can be undertaken an unlimited number of times, as long as the code of the
actuator is not locked in the sensor.
13 Maintenance
If the safety sensor correctly installed and used as intended, no maintenance
measures are required.
We recommend periodically carrying out a visual and functional test:
- Check the safety sensor and actuator for tightness.
- Check the connection cable for damage.
Damaged or faulty equipment must be replaced with original
spare parts!
In variant "unique", the safety sensor and actuator must be
replaced.
For the "individual" variant, a teach-in process must be performed
after replacement of the safety sensor OR the actuator.
13.1 Accessories
Suitable components for sensor variants with M12 pigtail connector:
M12 cable sets with plastic nut under item number K18G00.K.
An assembly wrench with preset torque is available under item number MS03
for ensuring an optimal connection between sensor and cable set.
For easy wiring in series connection of several safety sensors we recommend
our T-distributors:
- 350ATC6K serial
- 350ATD7K diagnostics / EDM
- 350ATD8K feed supply voltage
- 350AGA2K01 terminator
and connecting lines:
- K54G00.K male / female straight 4-pole
- K55G00.K male / female angled 4-pole
- K58G00.K male / female straight 8-pole
and cable sets:
- K14G00.K female straight 4-pole
- K18G00.K female straight 8-pole
14 Troubleshooting
Safety output faults
Flash code
Short circuit between safety outputs to ground or to
+24 V DC.
Cause
Wire breakage
- Switch off supply voltage.
Remedy
- Eliminate short/wire break at the output.
- Re-apply supply voltage.
Art.-Nr./Art. No./Réf./N° art/N° art.: 9010016B01M
Safety input faults
Flash code
Cause
Remedy
Safety input faults
Flash code
Cause
Remedy
Error overvoltage or undervoltage
Flash code
Cause
Remedy
Temperature outside the acceptable range
Flash code
Cause
Remedy
Incorrect actuator
Flash code
Cause
Remedy
Internal device error
Flash code
Cause
Remedy
If the errors described can not be resolved, the device must be replaced to
ensure the safety function.
15 Dismantling
Dismantle the safety sensor in a powered down state.
16 Disposal
Dispose of packaging and used parts according to the regulations of the coun-
try in which the device is installed.
17 Information about production date
Version/Version/Version/Versione/Versión: 1.0
Short circuit between safety inputs, to ground or to
+24 V DC.
Wire breakage.
- Switch off supply voltage.
- Eliminate short/wire break at the output.
- Re-apply supply voltage.
- EDM automatic:
Error on connected safety relay.
- EDM manual:
Start pulse does not take place in the defined area.
- All variants: Wire breakage.
- Switch off supply voltage.
- Check safety relay or set start pulse correctly,
check for broken wire.
- Re-apply supply voltage.
The supply voltage has not been applied in the defined
region.
- Switch off supply voltage.
- Ensure correct supply voltage and reconnect it.
The defined temperature range has been exceeded or
undershot.
- Switch off supply voltage.
- Ensuring proper ambient temperature.
- Re-apply supply voltage.
Incorrect actuator in the detection range of the sensor.
- Use correct actuator.
Internal device error.
- Switch off power supply and re-connect.
The date of manufacture can be seen on the safety sensor hous-
ing in the format "calendar week/year":
E.g. "37/14" = week 37/year 2014
Datum/Date/Date/Data/Fecha: 25.05.2016