Technical Data
EN
General
Parameter
Dimensions
Charging mode
Weight
Degree of protection
Mechanical strength
Pollution degree
Support for ventilation
Access
Maximum altitude
Max noise emission
Input cable cross section
Input cable diameter
Ambient operating temperature
Electrical
Parameter
Rated voltage
Rated current
Rated frequency
Protection class
Overvoltage category
Integrated RDC-DD
Parameter
Rated DC residual operating current
Making and breaking capacity
Rated conditional short-circuit
current
Normative standard
The Zaptec Pro T2S charging station has a maximum short-circuit current withstand capability of 10 kA.
When conducting the study and calculation required for any EVSE installations, ensure that the presumed
short-circuit current at the charging station's installation point is appropriate and adequately matched.
Test condition
Including backplate
Installation environment
According to IEC 61851-1 6 .3 .2 .2
According to IEC 61851-1 5 .4
With fan running
Symbol
Un
In
Symbol
Δ
I
dc
Δ
Im and I
m
Δ
Inc and I
c
Value
H: 392 W: 258 D: 132
Mode 3, case B
5
IP54
IK10
4
No
Restricted and non-restricted access
2000
47 .5
2 .5 to 10
10 to 18 .5
-30 to 40
Value
230/400
32
50
I
III
Value
0 .006
10
10
IEC 62955:2018
Unit
mm
kg
m
dBA
mm²
mm
°C
Unit
V
A
Hz
Unit
A
kA
kA
21