Tester prompts as following:
Main Menu
1.Battery Test
2.Cranking Test
3.Charging Test
4.Review Data
5.Print Data
6.System Setup
Cranking Test
Start Engine
CHARGING TEST (ALTERNATOR TEST)
Tester prompts as following:
Main Menu
1.Battery Test
2.Cranking Test
3.Charging Test
4.Review Data
5.Print Data
6.System Setup
Discharge Test
Increase RPM to
2500-3000 r/min
and
keep 10 seconds
Press ENTER
continue
1. Charging Test result: Normal
Charging system shows the generator output normal, no problem detected.
2. Charging Test result: Low
Charging volt of the charging system is low.
Check drive belt of the generator whether slip or running off.
Check the connection between generator and battery is normal or not.
If both of the drive belt and the connection are in good condition, follow the manufacturer's
suggestion to eliminate generator fault.
| www.bs-battery.com
Cranking Test
12V
24V
Cranking Test
RPM Detected
Charging
Test
12V
24V
Discharge
Test
Pls keep
it for 10
seconds
10s
EXIT for return.
ENTER for test
Cranking system, then
Disconnect clips for
Exit
Time
Voltage
Ripple Test
Hold for 10
seconds.
Press ENTER
continue
Charging Test
Keep RPM
stable for
10s.
Press ENTER
continue
Cranking Test
Cranking Test
780ms
10.13V
Cranking Normal
Ripple Test
Pls keep it for 10
seconds
10s
Charging Test
Pls keep it for 10
seconds
10s
7