BATTERY TEST RESULT
Battery test result includes 5 types as following:
Status >60%
Status >60%
Status <60%
Status <60%
Status = 0
1. GOOD BATTERY
Status: 96%
Charge: 98%
Internal R = 6.1mΩ
Rated: 500A
Battery OK
3. REPLACE
Status: 46%
Charge: 8 0%
Internal R = 35mΩ
Rated: 500A
Replace
5. CHARGE, RETEST
Status: 39%
Charge: 20%
Internal R = 30.1mΩ
Rated: 500A
Charge & retest
CRANKING TEST
Cranking test is the Engine ignition test. This test allows to check if the battery can provide
enough power to start the engine. It tests the battery instant voltage once start the engine.
If cranking voltage value is lower than 9.6V, the result is considered as abnormal.
If the result is higher than 9.6V, the result is considered as Normal.
| www.bs-battery.com
Voltage >12.4V
Voltage <12.4V
Voltage >12.4V
Voltage <12.4V
Voltage <12.4V,
Electric Current = 0A or 0 CCA
490CCA
12.64V
230CCA
12.68V
310CCA
12.08V
Good battery
Good, Recharge
Replace
Charge, Retest
Bad cell , replace
2. GOOD, RECHARGE
Status: 78%
Charge: 30%
Internal R = 7.2mΩ
Rated: 500A
Good, Recharge
4. BAD CELL, REPLACE
Status: 0%
Charge: 20%
Internal R = 45.2mΩ
Rated: 500A
Damaged , Replace
440CCA
12.20V
0CCA
10.64V
6