CHECK THE GAS TYPE THE DEVICE IS ADJUSTED FOR
Our appliances are certifi ed and regulated the natural gas (see technical plate). Conversion or adaptation to
a different type of gas must be performed by authorized personnel. Nozzles for different types of gas are in a
bag provided with the gas cooker and are marked in hundredths of mm (table of technical data pipes).
Nozzle replacement and pressure adjustment
Proceed as follows when replacing the main burner nozzle:
1) remove the control buttons from the front panel (fi g.1, note 1)
2) disassemble the front panel (fi g.1, note 3)
3) disassemble the drawer (fi g.1, note 2)
4) unscrew the nut (fi g. 2, note 5)
5) Pull the air intake (fi g. 2, note 6)
6) According to picture (fi g. 2) unscrew the nozzle from the main burner and replace with nozzles according
to table „TECHNICAL DATA"
7) Adjust the air intake for the relevant gas according to table „TECHNICAL DATA"
Proceed as follows when replacing the pilot burner nozzle:
Remove the parts (fi g.3, note. 8, 9, 10)
Adjust the pilot burner by loosening the safety nut (fi g.4, note 12) with a spanner, then unscrew the pilot
burner nozzle (fi g. 4, note 14) with the spring and replace with a nozzle for the relevant gas according to the
table. Tighten the nozzle cover with a spanner and adjust "economy" mode see text below.
Important:
After what was done adjusting the appliance to another type of gas, it is necessary to change the gas
indicated on the technical plate located in a visible location on the back of the device.
Adjusting fl ame at reduced performance „SAVING"
Flame at reduced performance „SAVING", can be set with screw placed in the valve body (note. 1, fi g. 5)
positioned next to valve shaft
For adjusting proceed as follows:
-
Remove the control knob (note. 1, fi g. 4) pulling towards you
-
Adjust the fl ame through hole with fl at screwdriver
Otvor pro
HOLE FOR FLAME
ADJUSTING
seřízení
fi g.
6
4
1
1
fi g.
5