Product HANDBOOK
Level of Insulation:
Primary mains circuits to secondary: 4.25 - 4.35kVDC
Safety Approvals:
nd
IEC/UL/EN60601-1, (2
Edition)
nd
UL/cUL60950-1 (2
Edition)
nd
IEC / EN60950-1(2
Edition)
CE marking when applied to any KMx15any product indicates compliance with the Low Voltage Directive
(2006/95/EC) in that it complies with EN60950-1 (2
Fusing: Internal fuses (F1): Single fuse in the L line, T2AL, 250V, not Serviceable
External fusing: Recommended 2A/250V slow blow
Input Parameters:
Standard
Rated input voltage
Input voltage range
Input frequency range
Maximum input current
115/240VAC
Inrush current
Output Parameters:
Model
15W
Single O/P
15W
Dual O/P
15W
+5/+12/-12
Triple O/P (Note 1)
+5/+15/-15
Note 1: For Triple output modules the main 5V output is isolated from the other ±12V or ±15V outputs (dependant on model). A minimum
load of 25% is required on the ±12V and ±15V outputs.
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if
the total output voltage exceeds 60Vdc
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be
considered non-SELV.
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to
service engineers making inadvertent contact with the output terminals in the end equipment.
KM15 Series
nd
100-240 VAC
90 – 264VAC
130mA/
0.70mA
20A max at 230VAC (25° C cold start)
Vout (V)
Output
current (A)
3.3
4.4
5
4.4
9
2.4
12
1.8
15
1.4
24
0.9
+5/-5
1.5/1.5
+12/-12
0.625/0.625
+15/-15
0.5/0.5
2/0.2/0.2
2/0.15/0.15
Edition).
60950-1
47 – 63Hz
270mA/
400mA/
0.130mA
0.200mA
Max
capacitive
load (µ)
40000
10000
3000
1100
1000
820
4700
560
500
10000/470
10000/600