Alarm signals
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
"COOL FIRE": in the event of an
even very short lack of current, the
stove switches off. As soon as the
power supply is back, the stove will
start a cooling cycle and the display
will show the words "Cool fire".
After completing the cooling cycle,
the stove will start up again. NOTE: If
your stove is supplied with a remote
control and there is a lack of
current, remember to program the
eventual switching on and off
times again. In the event of a lack
of current, the stove will loose any
previous time settings.
Once the power supply is back,
press the key SEND on the remote
control to retransmit the automatic
programming you previously set to
the stove.
"SERV": the signal "Serv" on the
display means that the stove has
reached 1200 hours working. Please
contact
arrange
maintenance.
"ALARM NO ACC": this alarm
occurs when the time foreseen for a
light up (around 15 minutes) passes
and the smokes temperature is still
too low. This can occur also when
there is not enough pellets flow to
light up the unit. Press the key On/
Off on the control board to reset the
alarm. Wait until the cooling phase
is completed, clean the brazier and
start up with a new switching on.
"ALARM NO FIRE": this alarm
occurs in the event the stove switches
off during its working phase (for
example if there is no pellets left in
the pellets tank).
Press the key On/Off on the control
board to reset the alarm. Wait until
the cooling phase is completed,
clean the brazier and start up with a
new switching on.
service@gimeg.nl
a
supplementary
"ALARM FAN FAIL": this alarm
occurs in the event the smokes
ejector is broken or the pcb cannot
detect the speed of the smokes
exhaust fan.
In this case press the key On/Off
to reset the alarm and contact the
technical assistance.
"ALARM SOND FUMI": this alarm
occurs in the event the sensor for
smokes temperature is broken or not
connected. You will read the words
Alarm Son fumi on the display. In this
case press the key On/Off to reset
the alarm and contact the technical
assistance.
"ALARM DEP SIC FAIL": this alarm
is signalised by the Leds ALF and
ALC blinking on the control board.
It indicates two different possibilities:
an obstruction in the flue or a
to
possible overheating of the stove.
In both cases the motor reducer
to load the endless screw stops
working and the stove switches off.
Press the key On/Off to reset the
alarm. Check the possible activation
of the manual reset thermostat on
the back of the stove (4). Unscrew
the safety cap and press the key.
In the event you have the same
problem more than once, please
contact the technical assistance.
80