REMARKS:
- the appliance must be installed by a qualified technician in possession of the technical and professional
requirements according to the DM37/2008 that, under its responsibility, to ensure compliance with
the rules of good technique.
- you need to keep in mind all laws and national, regional, provincial and municipal laws of the
country in which you installed the device
- check that the floor is not flammable: if necessary use a suitable platform
- in the room where the generator must be installed to heat must not pre-exist or be installed with
an extractor hood or ventilation ducts of the collective type.
Should these devices be located in adjacent rooms communicating with the installation, and
'prohibited the simultaneous use of the heat generator, where there is a risk that one of the two
rooms being placed in depression than the other
- it is not permissible to install in bedrooms or bathrooms.
Control board
1. Temperature or power decrease
2. Temperature or power increase
3. Key On/Off
4. Receiver
5. Led alarm ALC
6. Led alarm ALF
7. Led chrono-thermostat
8. Led temperature ok
9. Led pellets loading
10. Led resistance
11. Display LED 7 segments
12. Led On/Off
Display keys and functions
1. Using the key on the menu Set temperature, you can decrease the temperature from a maximum
value of 40 °C to a minimum value of 7 °C.
With the key on the menu Set power, you can decrease the working power from a maximum value
of 5 to a minimum value of 1.
2. Using the key on the menu Set temperature, you can increase the temperature from a min. value
of 7°C to a max. value of 40°C.
With the key on the menu Set power, you can increase the working power from a min. value of 1
to a max. value of 5.
3. Keep the key pressed for 2 seconds to switch the stove on or off.
4. Sensor receiving the settings of the remote control.
5. The led blinks in the event of a malfunction or alarm.
59
6
5
AL C
AL F
7
1
4
2
8
12
9
11
3
10