Rescue equipment shall be stored in a clearly marked area and be readily accessible for rescue
purposes.
Equipment, which is damaged or in need of maintenance, should not be stored in the same area as
usable equipment. Prior to using equipment which has been stored for long periods (greater than
one year) of time, a detailed inspection should be performed by a competent person. heavily soiled,
wet or otherwise contaminated equipment should receive proper maintenance (e.g. drying and
cleaning) prior to storage.
6. Inspection of the rescue equipment
Equipment shall be inspected by the rescuer before each use and additionally by a competent
person other than the rescuer at intervals of no more than one year.
Inspection criteria for the equipment shall be set by the rescuer's organization. Such criteria shall
equal or exceed the greater of the criteria of the standard or the manufacturer's instruction.
Inspection criteria shall be kept current in relationship to changing patterns or conditions of use.
The purpose of two-level inspection of equipment is to provide two independent means for
detecting and preventing the use of defective, damaged or improperly maintained equipment. If
such equipment conditions are observed by the competent person's inspection, measures should
be taken to provide the rescuer with additional training or retraining in equipment inspection,
maintenance, use and storage.
The frequency of periodic inspections by a competent person should be established by the
rescuer's organization based upon careful consideration of relevant factors. Such factors include
the nature and severity of workplace, conditions affecting the equipment and the modes of use and
exposure time of the equipment.
Documentation of equipment inspections shall be maintained by the rescuer's organization.
This documentation shall include at a minimum the identity of the equipment, inspection date,
name of the competent person conducting the inspection and the results of that inspection.
7. Utilization period
The utilization period depends on the respective conditions of use. Based on our experiences so
far, you can expect the ropes to have a utilization period of 8 years under normal conditions of use.
8. Preauction
User manuals / logbooks are provided for each system or component. They have to be kept close
to the equipment. If the equipment is sold to another country, the re-seller has to provide
instructions for use, maintenance, periodic inspection and repair in the language of the other
country.
Please also follow the instructions for use of the products that are used in connection with the
RG11, RG11/A, RG11/DA descender device and the accident prevention rules applicable in each
case.
The device may only be used by a person that is instructed and trained in safe practice. Only a
regular practical training can guarantee a safe use. For every expected rescue scenario a rescue
plan is needed.
Without written permission of the manufacturer changes or addition to the device are not allowed.
The device may only be used under conditions described in this manual (load, descending height,
temperature range).
After long descent operations the device can get very hot and damage the rope .
For this reason only touch the device with gloves.
Every combination of different equipment can cause unexpected dangerous situations that have a
negative influence on safety of the user.
Anchor points must be located above the user of the device and have a break strength of at least
10 kN in accordance with the EN 795 standard or in accordance with local and/or national
requirements.
In case of any doubts about the safe condition or the safe function of the device it has to be taken
out of use immediately.
Healthy limitations (f.e. heart- or circulation problems or use of medicines) can have a negative
influence on the safety of the user in usual and emergency cases.