Safety
The inverter is internally protected against
overloads and short circuits. Should this
protection fail, the inverter is equipped with a fuse
(fire protection). If the fuse is broken, qualified
technicians should control the installation and
change the fuse.
Internal fuses
Fuse
Inverter SOLO (mod.)
50A
48V-1200W
80A
48V-2300W
100A
48V-3500W
2*100A
24V-2300W
2*125A
24V-3300W
The use of higher fuse value will not improve
the performance of the inverter and will
degrade safety protection!
Maintenance
The SOLO inverters do not need any special
maintenance. The casing may be cleaned with a
damp cloth (not wet).
In the case of malfunction, the inverter should be
sent to the salesperson for control.
SOLO3DEE
Legislation
In all cases the assembly and installation must be
done by qualified technicians, observing the
national requirements and rules stipulated. You
will find complete information about this in the
relevant institutions.
Limitation of liability
CRISTEC cannot control the installation, use and
maintenance of the inverter. Thus, we are not
responsible for damages, costs or losses resulting
from an installation which is not in accordance
with the regulations or inappropriate use or
maintenance.
The customer is always responsible for the use of
the inverters CRISTEC.
This device has not been designed and is not
warranted for use in life support apparatus or any
other critical apparatus with potential risks of
serious harm to people or to the environment.
We do not accept any responsibility for any
violation of patent rights or other third person
rights resulting from the use of the inverter.
CRISTEC reserves the right to modify their
products without previous notice