Product presentation
The inverters of the SOLO series are presented
fully equipped, with battery cables, 230V cable
and the user's handbook.
Location
The place where the inverter is to be mounted
should meet the following requirements :
•
Out of reach of non-authorised persons.
•
In a dry place with no condensation.
•
Not directly on top of the batteries.
•
Adequate ventilation. No inflammable material
in the same room.
•
Do not lay anything on the device.
•
An area of 20 cm from the top and the bottom
of the device should be kept clear for the
ventilation.
Fitting
The inverter has been designed to be used only in
a vertical position and against the wall
inverter is fitted using the four external holes (∅
5,5 mm).
The fitting screws are not supplied with the
inverter.
3500W
3300W
2300W
1200W
200mm
Beware :
The casing of the inverter can reach high
temperature ( 80 °C )
SOLO3DEE
Connection
• Check the switch (4) is in " OFF " position.
• First connect the 230V outlet (6) to the user
Check the tension and polarity of the battery !
• The tension of the battery should coincide with
• Battery connection :
This connection should be done very carefully
observing the polarity in order not to damage
the device.
• Check that the connections are fixed correctly.
Use
After connecting the inverter, make sure the user
devices are correctly plugged in and that there is
no possible contact between the " Line OUT " (6)
and a person.
The
.
The working device generates high tensions
which could be fatal!
The inverter can be activated by moving the
switch to the 'Auto" position. The 'on' indicator -
green LED -(3) is illuminated.
If no user device is connected, the LED blinks
after some seconds, which indicates that the
"standby" mode has started. If a user device is
plugged in, the green LED remains illuminated,
indicating the uninterrupted presence of 230V in
the outlet. If you wish to deactivate the standby
mode, put the switch in "Lock" position. The
inverter will be then working continuously.
Warning :
With the "lock" mode, the no load
consumption of the inverter is 15 to 20 times
greater !
device, so as to prevent any possible
accidental contact.
that mentioned in the technical characteristics
of the inverter.