SAFETY INSTRUCTIONS
Check that the infeed tube is used correctly.
Do not drag the tool connected to the power
supply by pulling the tube. Keep the tube
away from sources of heat and sharp objects.
Fasten the part to be worked.
devices to keep the part still. This is safer than
using your hands and in this way they will both
be free for working with the tool. Check that a
firm resting point is always available and that
the position is well-balanced.
Always keep a good grip
the tool, using special auxiliary devices where
necessary. This will serve to reduce body
vibration.
Accessories being operated.
parts and/or accessories of the tool which are
moving or working.
Pay attention.
Always pay attention to what
are you doing. Proceed with care. Do not work
when you are tired.
Look after the tools.
in good condition so that better results may
be obtained safely. Never remove protection
or silencers from the tool. Follow instructions
for maintenance and for replacing the
accessories.
Use and assembly of the accessories.
should be done according to the machine
instructions manual. The use of accessories or
assembly other than those recommended may
cause personal harm.
Switch off the power supply.
session and before performing calibration,
maintenance or replacement operations on
the accessories such as impact sockets, etc.,
you are recommended to switch of the power
supply to the tool.
Use fastening
on the handle of
Do not touch
Keep them clean and
This
After each work
Remove the service keys.
tools, always check that the service or adjusting
key has been removed.
Check damaged parts.
are received, check that the packaging is
intact and there are no signs of knocks or
tampering. Before using the tool, carefully
check that the safety device and other parts
are in perfect working conditions.
Check that the moving parts are not
damaged, that they are free to move, and
check any other conditions that could limit
the operation of the tool.
A damaged protective device or other
component must be replaced or repaired
by an authorised Servile Centre unless
otherwise indicated in this manual.
The tool does not emit non-ionizing
radiation.
IMPORTANT.
The use of accessories and spare
parts other than those recommended in this
manual may cause personal harm.
Do not alter any element of the machine
or remove protective or safety devices,
or elements for checking the outgoing air
flow (filters, deflectors, etc.) without explicit
authorisation from PAOLI.
Stop work
immediately should vibrations
or strange noises occur, or if the tool starts
operating differently.
The tool should be repaired by a qualified
personnel.
This compressed air tool complies
with current safety regulations. Repairs must
be done by qualified personnel, using original
spare parts, otherwise serious harm may be
caused to the operator.