Anleitung MKA 3501 E SPK 1
Use the foam parts and shorten them if required.
Guide the exhaust air hose through the opening in
the foam to the outside. Secure the window so that
the foam is kept firmly in place.
Note: Take appropriate precautions to prevent
unauthorized entry through the window.
B) Installation of the exhaust air hose
through the window pane or the wall
Wall or window pane
Bushing ring
Cut or drill a hole of approx. 130 mm diameter
though the window pane or the wall.
Insert the bushing ring from the outside to the
inside and fasten.
Feed the exhaust air hose through the bushing
ring.
When the system is not being used, fit the cap on
the bushing ring on the outside.
C) Draining off the condensation water
with the water tank
ALL OF THE CONDENSATION WATER MUST BE
DRAINED OFF BEFORE YOU EVER RELOCATE
OR STOP USING THE DEVICE:
Draining off the condensation water with the
tank.
Note on MKA 2000 M / MKA 3000 M
When the condensation water tank is full the
"Condensation water tank full" indicator lights up and
18.02.2005
7:18 Uhr
Seite 15
the compressor switches off automatically. Only the
fan motor continues to run. The cooling function
stops.
Note on MKA 3501 E
When the condensation water tank is full the
compressor and the fan motor shut down. The
"COMP" LED flashes.
Empty the tank as described below:
1. Pull out the mains plug.
2. Slide the tank (1) under the drainage screw (2).
3. Unscrew the drainage screw (2).
4. Remove the bung (3).
5. The condensation water drains out into the drip
bowl.
6. Once the condensation water has been completely
emptied, fit the bung (3) and the drainage screw
(2) back on again.
7. The device is then ready to be used again.
Condensation water hole
D) Draining off the condensation water
with the condensation water hose
1. Pull out the mains plug.
2. Unscrew the drainage screw (2).
3. Remove the bung (3).
4. Fit the condensation water hose and secure with
the clamp.
5. The drainage hose can be extended with a hose
with a diameter of 18mm. If you do so, make sure
you use a suitable connector.
Note:
The drainage hose must run to the outside with a
GB
15