11 - MAINTENANCE
11.14 REPLACE OR CONTROL THE ELECTRIC
HEATER
If the replace or control of the electric heater
•
Remove power supply
•
Remove frontal cover (A)
•
Unscrew the screws and remove the cover cap (B)
•
Turn off the water inlet valve (C)
•
Open hot water tap for decrease the pressure of the
storage tank.
•
Open tap (D)
•
Empty the storage up to point (E)
•
Disconnect the cable from the electric heater
•
Remove and replace the electric heater (If faulty)
•
Install the electrical resistance and make sure effective
sealed.
•
Check that there are no water losses from the fitting
•
Restore the electric connections
•
Put the cover cap (B) and fix
•
Put de frontal cover (A)
•
Open the water inlet tap (C) untill water flows out from
outlet tap, then turn of water outlet tap.
•
Power on then restart the unit.
E
C
D
11.15 CONDENSATE DISCHARGE
Dust and deposits could cause obstructions .
In addition in the pan can proliferate microorganisms and
moulds.
It is very important to provide a periodic cleaning with
appropriate detergents and in case a disinfection with
sanitizing products.
After cleaning pour water into the pan to ensure a regular flow.
A
B
Electric heater
Drain pan
52