Printer Parts
1
Type A
DIP Switch Tables
Serial
SW
Function
1-1
Data reception
error
1-2
Receive buffer
capacity
1-3
Handshaking
1-4
Word length
1-5
Parity check
1-6
Parity selection
1-7
Baud rate
1-8
Busy condition
2-1
Print column
selection
7 × 9 font/
9 × 9 font
2-2
For internal use. Do not change.
2-3
Type A For internal use. Do not change.
Types B & D Pin 6
reset signal
2-4
Type A Undefind.
Types B & D Pin 25
reset signal
2-5,
For internal use. Do not change.
2-6
2-7
Type A Pin 6 reset
signal
Types B & D For internal use. Do not change
2-8
Type A Pin 25
reset signal
Types B & D Undefined.
2
Type B and
two color
Type D
ON
OFF
Ignored
Prints"?"
40 bytes
ANK Model:
1000 bytes
Multilingual
model: 512 bytes
XON/XOFF
DTR/DSR
7 bits
8 bits
Yes
No
Even
Odd
4800 bps
9600 bps
BUSY when
BUSY when
receive
offline or receive
buffer is full
buffer full
42/35
40/33
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
3
Single
color
Type D
Parallel
SW
Function
1-1
Auto line feed
1-2
Receive buffer
capacity
1-3-
Undefined
1-7
1-8
Busy condition
2-1
Print column
selection
7 × 9 font/
9 × 9 font
2-2
Internal use. Do not change.
2-3
Type A Internal use. Do not change.
Types B & D Undefined.
2-4
Type A Undefined.
Types B & D Pin
31 reset signal
2-5,
For internal use. Do not change.
2-6
2-7
Type A Undefined.
Types B & D Internal use. Do not change.
2-8
Type A Pin 31
reset signal
Types B & D Undefined.
ON
OFF
Enabled
Disabled
40 bytes
ANK Model:
1000 bytes
Multilingual
model: 512 bytes
BUSY when
BUSY when offline
receive
or receive buffer
buffer is full
full
42/35
40/33
Enabled
Disabled
Enabled
Disabled