The "Miele Service Documentation (MSD)" service application is required when carrying out maintenance work on
the appliance
The safety instructions and warnings in the Miele Service Documentation (MSD) for the corresponding model must be
observed.
Work on the appliance must be carried out in accordance with the work instructions.
Air flap installation instructions
Reason: if high or low pressure in the vent ducting prevents the fan impeller from standing still, an air flap must be
integrated in the vent ducting. High or low pressure in the vent ducting can trigger fault F218.
Special tool/s
No.
Mat. no.
Designation
1
Cordless screwdriver with chuck
1
HSS drill bit, 3 mm
1
TX 20 screwdriver
Included parts
No.
Mat. no.
Designation
1
Electric air flap
1
Screw, M4 x 12.5
Installing the air flap
The air flap is a non-return flap with motorised opening. The air flap closes under spring load within approx. 8 seconds
without power applied. The air flap must move to the open position (90° rotation angle) within approx. 8 seconds. The
8 seconds start when the dryer fan starts.
A
If there is no XCI box installed, install and commission an XCI box in accordance with the installation instructions.
A
Disconnect the tumble dryer from the power supply.
A
Place the air flap between the tumble dryer and the vent ducting. Pay attention to the specified flow direction (see
sticker on the air flap).
A
Use the M4 x 12.5 screw to fasten the air flap to the vent duct of the tumble dryer. Drill a 3 mm diameter hole for this
purpose.
A
Guide the air flap connection cable into the XCI box and secure it with the strain relief.
A
Connect the air flap to contacts 3.3 and 3.4 in the XCI box, see [> 4].
A
If several components are connected to the XCI box, pay attention to the maximum current carrying capacity of 4 A.
A
Switch on the tumble dryer.
A
Switch to the supervisor level.
A
For machines with Performance Plus controls (touch display): go to
Additional fan
option to
A
For machines with Performance controls (7-segment): set the "Additional external fan" option (see operating
instructions for option number) to -01.
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
.
On
Umbau- und Montageanweisung
External applications
3 von 20
and set the