Télécharger Imprimer la page

fadini Elpro 42 Mode D'emploi page 16

Masquer les pouces Voir aussi pour Elpro 42:

Publicité

Les langues disponibles

Les langues disponibles

Elpro 42
GB
EXCLUDING GATE LEAF DELAY ON PROGRAMMING
(when it is required that both gate leafs be opened simultaneously and for single gate applications where one motor only is involved).
Once all the electrical connections to the control unit have been properly made (following the instructions included in the box) with all of the safety
and command accessories as required, programming can be carried out.
NOTE VERY WELL: all of the green LEDs must be ON, otherwise check the connections with any accessory, mainly the NC contacts
!
of the safety devices installed (contacts of the inner and outer photocells, stop contact, safety edges, ...).
PROGRAMMING THE UNIT TO OPERATE ON NO GATE LEAF DELAY MODE
LP
1)
5 seconds
LP
2)
1 pulse
LP
LP
3)
LP
4)
Adjust the speed, force and dwell trimmers according to the actual site requirements and type of gate to operate, in full respect of the
"the Force Limitation directive in compliance with EN 12453 and EN 12445 norms".
IMPORTANT: any time the speed and force trimmers are readjusted, it is required that programming be made anew.
ADJUSTING SPEED IN SLOWDOWN PHASE
Default speed at the end of slowdown phase is 25%
It is possible to adjust the final speed of the slowdown phase as described in the steps below. Depending on the application requirements, an even
softer stop of the gate at the end of the permitted stroke can be achieved or, on the contrary, a more vigorous one to facilitate latching in case an
electric lock is fitted.
NOTE WELL: speed readjustments will be executed following any open/close/radio pulse.
!
Readjust speed and then give an open/close/radio command to assess functioning.
1)
DIP-SWITCH N° 6:
ON: speed adjustment in slowdown
phase enabled
6
3)
DIP-SWITCH N° 6:
OFF: speed adjustment desabled and
latest setting saved as required in
6
slowdown phase
ELECTRONIC CONTROLLER FOR DARDO 424 AND FOX 724
GATE OPERATOR ON DOUBLE SWINGING GATES
LP
LP
LP
LP
of the maximum speed.
2)
4)
Press and hold the programming button for 5 seconds (until the LP led
starts flashing): programming mode is thus accessed.
Pulse just once: the LP led light is steady
on, wait.
After 10 seconds the LP led light goes off
and the gate leaves open simultaneously
untill the gate stop is reached in open
limit position.
With the gate in the open limit position the
LP led goes on with steady light: wait about
10 seconds (do NOT press the button). The
LP led goes off and the gate leaves move in
close direction until gate stop is reached.
LP led OFF and flasher OFF indicate that
programming is finished.
50%
maximum speed
20%
70%
maximum
maximum
speed
speed
Speed trimmer
16
With the gate in stop position, set the speed trimmer
to the required value and give an open/close/radio
command to assess functioning.
In this mode, the trimmer controls maximum speed
during gate travel. Therefore it is to be adjusted to the
position/value as set before step 2.

Publicité

loading