Télécharger Imprimer la page

fadini Elpro 42 Mode D'emploi page 13

Masquer les pouces Voir aussi pour Elpro 42:

Publicité

Les langues disponibles

Les langues disponibles

Elpro 42
GB
Accessory
24 V - max 500 mA output:
24 Vdc flasher:
24 Vac/dc output
for DSA control
Photocells projectors
Input for
safety edge
in opening
Input for
safety edge
in closing
Input for pedestrian
opening
(M1 motor only)
Electric lock output
12 Vdc
ELECTRONIC CONTROLLER FOR DARDO 424 AND FOX 724
GATE OPERATOR ON DOUBLE SWINGING GATES
Electrical connections
24 Vac output
9 10
max. load 500 mA:
n° 1 radio receiver
n° 2 pairs of photocells
n° 1 led Chis 37/Chis-E 37 or DGT 61 PCB
11 12
24 Vdc output for the flasher
24 V output to power supply the projectors of the
13
14
photocells (power supplied in parallel) on DSA control:
Device for Safety Autotest = before gate operation,
provided that this function is enabled. All of the safety
devices are tested and assessed to be free from any
obstraction, otherwise the operator is not allowed to
start.
15
17
In series if
NC mechanical type
16 17
In series if
NC mechanical type
17 18
Input for
pedestrian
opening
19 20
12 Vdc output
-
+
for the electric lock
15
17
8,2 kΩ
In parallel if
8,2 kΩ resistive type
16 17
In parallel if
8,2 kΩ resistive type
M1
13
Dip-switches and LED indication
of the various functions
DIP-SWITCHES N° 4 and 8:
ON: pre-flashing before opening
4
OFF: no pre-flashing
ON: flasher disabled in dwell time on automatic
mode of operation (Dip 3 = ON)
8
OFF: it flashes in dwell time
on automatic mode of operation (Dip 3 = ON)
DIP-SWITCH N° 10:
ON: DSA control enabled on photocells.
It is necessarily required that the photocells
10
projectors be power supplied to 13-14 terminals
OFF: no DSA control on the photocells
L15 green ON = safety edge in opening.
It goes OFF whenever the safety edge is
activated
L16 green ON = safety edge in closing.
It goes OFF whenever the safety edge is
activated
DIP-SWITCH N° 7:
ON: stroke reversing pulse enabled for 2 s
in opening
7
OFF: stroke reversing pulse disabled
For a proper latching of the
!
electric lock, adjust slowdown
speed accordingly .

Publicité

loading