Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Measuring tape
Pencil
Phillips screwdriver
Parts Supplied (not shown to scale
Rear duct
Bottom duct
19# screw
93# screw
ST3*25(4+2 extra)
(
)
M4*10
8+3 extra
Location Requirements
The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of
15
3
/
" (10cm) between the top of the lower oven cutout and the
16
microwave oven cutout floor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36
cutout floor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 2" (5 cm) below the
15
cutout floor (3
/
" [10 cm] for installation above a built-in oven),
16
and a clearance of at least 2" (5 cm) above the cutout opening.
2"
(5 cm)
B
2"
(5 cm)
D
E
A. Upper cabinet
B. Microwave oven cutout
C. Lower oven cutout
2
INSTALLATION INSTRUCTIONS
Drill
7/64" drill bit
Trim kit frame
Rails (2)
123# screw
(
)
ST4*16
7+3 extra
1
/
" (91.6 cm) from the floor to the
16
A
B
C
1
/
"
36
16
(91.6 cm)
D. Lower cabinets
E. Floor
Required Cutout Dimensions
For minimum depth requirements, see chart.
1
17
/
"
8
(43.5cm) min
3
17
/
"
16
(43.7cm) max
15
3
/
"
16
(10cm)
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
D. Cutout centerline
Receptacle Location
Within recommended
region
Outside recommended
region
NOTES:
Depth requirements depend upon receptacle and its location
within or outside of recommended region. See illustration and
chart above.
Height dimension is critical: 17
(43.7 cm) minimum.
Width measurement has ±1/16" (2 mm) tolerance.
15
3
/
" (10 cm) minimum dimension is from lower oven cutout
16
ceiling to microwave oven cutout floor.
Trim kit frame extends
cutout opening.
2"
(5 cm)
15
3
/
"
16
(10cm)
13
18
/
"
16
(47.78cm)
*27" (68.6 cm) trim kit
**30" (76.2 cm) trim kit
6"
(15.2cm)
1
23
/
"
8
(58.7 cm)
C
D
location (no less than 6" [15.2 cm] to
the right of cutout centerline)
Minimum Depth
9
21
/
" (54.8 cm) with flush receptacle;
16
9
23
/
" (59.8cm) with non-flush receptacle
16
9
23
/
" (59.8 cm) with flush receptacle;
16
9
25
/
" (64.9 cm) with non-flush receptacle
16
1
/
" (43.5 cm) minimum,17
8
⁄₁₆" (2.14 cm) above and below the
13
13
26
/
(68.08cm)*
*
"
16
3
29
/
(75.48cm)**
*
"
4
7
22
/
"
8
(55.59 cm
)
3
3
/
" (8.64 cm)
8
9
3
/
"(9.09 cm)
16
2
5
5.89cm) *
"(
*
16
3
3
/
"(9.59cm)**
4
⁄
1
1
8
13
/
"
16
(2.14 cm)
A
13
/
"
16
(2.14 cm)
B
3
/
"
16
11
9
/
"
16
(29.38 cm
)
(2.92 cm)