Télécharger Imprimer la page

Balluff BAE SA-XE-051-XR-SA39 Notice D'utilisation page 4

Publicité

Les langues disponibles

Les langues disponibles

Instruction manual BAE SA-XE-051-XR-SA39
Dimensions
Connection diagram
intrinsically safe sensor
accord. to
NAMUR, IEC 60947-5-6
Function display and controls
green
yellow
red
Programming
switch
Programming
The function of the output circuit is
determined by the programming switch.
* State defined in IEC 60947-5-6
BA-S36114-GB-2020-17
hazardous area
(+)
(–)
Control circuit
PWR
OUT
CHK
NO
NC
NO
NC
non hazardous area
BAE-SA-XE-
1 (+)
051-XR-SA39
2 (–)
Marking
LED
Specification
CHK
red
lights up with cable break
or short circuit
OUT
yellow lights up when the relay is energized
PWR
green Supply voltage connected
Switch position NO
Input (1,2)*
Relay output (9,10,12)
12-9
conductive
closed
non-conductive
open
Switch position NC
Input (1,2)*
Relay output (9,10,12)
12-9
conductive
open
non-conductive
closed
Page 3
Supply voltage
15
+
24 V
16
0.02 A; 50 / 60 Hz
10
Relay output
9
12
F: 5 A (F)
according to
IEC 60127
12-10
open
closed
12-10
closed
open
Dok.-Nr. 947088-EN/FR-D20
Subject to modification