Instruction manual BAE SA-XE-051-XR-SA39
Technical data
Certificate number
HazLoc marking
Control circuit / maximum values
Um
Uo
Io
Po
Capacitance and inductance / maximum values
Group
IIC
IIB, IIIC
IIA
Control circuit
Contact circuit / maximum values
Voltage max.
Current max.
Load cos φ
L / R
Rated voltage range
Operating voltage range
Rated current
Power consumption
Rated frequency
Fuse in supply terminal (15), (16)
Overvoltage category
Transient Overvoltage in supply
Degree of pollution
Degree of protection IEC 60529
Ambient temperature range
Height above sea level
Air humidity
Test voltage
Electrical connection
BA-S36114-GB-2020-17
CSA 20 CA80037012
[A/Ex ia Ga] IIC
[A/Ex ia Da] IIIC
Associated Apparatus connects to
Class I, Division 1, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class III, Division 1
30 V DC
9.6 V
10.1 mA
24.2 mW
linear characteristic
Co
Lo
0.84 µF
5.00 mH
3.40 µF
20.00 mH
4.90 µF
20.00 mH
NAMUR, IEC 60947-5-6
250 V AC
60 V DC
4 A
0.8 A
≥ 0,7
≤ 200 ms
24 V DC
21.6 - 26.4 V DC
0.02 A
0.5 VA
50/60 Hz
up to 20 A approved branch circuit breaker is
required in each line
II
max. 2500 V
PD2
IP 20
–20 °C ≤ Ta ≤ +60 °C
max. 2000 m
max. 80% r.H. non-condensing
1500 V / 50 Hz / 60 s
terminal screws, wire cross-section 0.14...2.5 mm2
Page 2
24 V DC
4 A
≤ 200 ms
Dok.-Nr. 947088-EN/FR-D20
Subject to modification

Publicité