Télécharger Imprimer la page

Brizo MultiChoice T60405-PC Manuel Du Propriétaire page 5

Publicité

Les langues disponibles

Les langues disponibles

60 Series Installation
Showerhead and Tub Spout Installation
2
FOR SHOWERHEAD INSTALLATION:
top outlet (1) to shower arm (2) with proper fittings.
To prevent damage to finish on shower arm,
insert wall end of shower arm into shower flange
(3) before screwing arm into riser connection.
Thread showerhead (4) onto shower arm. Apply
plumber tape to pipe threads on both ends. Do not
overtighten showerhead.
FOR TUB SPOUT INSTALLATION:
(13 mm) threaded pipe nipple (1) to extend past
finished wall (2) per dimension (3). Connection
of deck mount spouts to in–wall valves is not
recommended. Neither is the use of hand showers
connected to tub spouts in a tub/shower push
button diverter combination, or hand showers
connected in lieu of a tub spout to a tub / shower
valve. Piping between valve body and tub spout
must be a minimum of 1/2" (13 mm) copper pipe or
1/2" (13 mm) iron pipe in a straight drop no less
than 8" (203 mm) but no more than 18" (457 mm)
long with only one iron pipe or copper 90 degree
RP49126s
s Specify Finish
(3) = 5 3/8" ± 1/16" (136.5 mm ± 1.5 mm)
RP54874s
s Specify Finish
(3) = 9/16" ± 1/16" (14.3 mm ± 1.5 mm)
RP74644s
s Specify Finish
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
80454
Rev. C
3
2
4
Install 1/2"
1
3
2
1
3
2
1
3
2
1
FOR RSVP
SHOWER ARM INSTALLATION:
threaded pipe nipple to extend beyond the finished
wall 3/8" to 1/2". Apply plumber tape to thread on pipe
nipple and screw brass adapter (1) securely onto
Connect
nipple. Apply plumber tape to outlet end of shower
arm and screw showerhead (2) onto the shower arm
(3), using provided wrench (4) to tighten securely.
Check position of set screw on top of shower arm (3)
making sure it is not sticking through to the inside
opening where it could interfere with the assembly.
Slide shower arm and head assembly over the
adapter and tighten set screw against the adapter.
elbow to the tub spout nipple. Apply plumber tape to
threads on pipe nipple, add sealant to groove in back
of wall escutcheon (4) and screw on tub spout.
RP49094s
s Specify Finish
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
RP49345s
s Specify Finish
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
RP64084s Tub Spout & Flange/
Pull Down Diverter
RP49761s Spout Flange
s Specify Finish
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
RP78581s
s Specify Finish
(3) = 3/8" ± 1/16" (9.5 mm ± 1.5 mm)
4
3
1
4
2
AND SOTRIA SHOWERHEAD AND
®
3
2
3
2
3
2
3
2
Install a 1/2"
1
1
1
4
1

Publicité

loading