1.
Position the pedestal on the floor standing upright.
2. Mount the complete sealer assembly to the top of
the pedestal and attach with four screws.
3. Position spring under the sealer's upper level. The
pull-rod goes through the spring and is fastened to
the upper level.
4. With foot pedal metal rod in hand, gently push
down upper jaw to meet with lower jaw. While jaws
are compressed, reach under unit and hook the
metal foot pedal rod into the bottom of the spring
bar where the 1/2" hole is exposed.
5. With jaws still compressed, lift up the foot pedal to
45˚ angle and slide the metal foot pedal rod into
one of two pre molded slots. This will create tension
on the foot pedal and cause the pedal to stand
upright at 45˚.
6. Sealer is now ready to be used.
TO INSTALL OPTIONAL WORKING TRAY AND PLATE
1.
Remove center screws from bottom sealing jaw.
2. Install the working plate as shown.
NOTE: Before operating, check the heater
(heating element), Teflon cover, Teflon
adhesive, and the sealing pad (silicon rubber).
1.
Insert the Power Cord into the correct receptacle (110V).
2. Turn the power switch ON.
3. Set the timer knob to lowest setting. Always start with
a low setting and increase gradually. Thicker bags
need a higher setting.
4. Place the end of the bag under the sealing arm
and press the pedal down gently, but firmly. Hold for
2-3 seconds. The red light will go out when sealing
time is complete.
a. If the seal is broken or damaged, decrease the
sealing time.
b. If the seal is not fully welded, increase the
sealing time.
c. If the sealing material sticks to the sealing pad,
decrease the congealing time.
d. If the width of the seal is not perfect or does
not match the size of the element, increase the
congealing time. (Congealing time is necessary
for sealing.)
Page 2 of 9
ASSEMBLY
Sealer
Assembly
OPERATION
5. When red light goes out, keep pressing the pedal for
2-3 seconds.
NOTE: Must wait until congealing time is up.
6. Release the Pedal.
ADDITIONAL INFORMATION
1. Always keep the sealer clean. Remove any residue
found on the platform and Teflon cover. Silicon spray
may be used for this purpose.
2. When replacing the heating elements, always check
the condition of the bottom Teflon tape.
3. A worn Teflon Adhesive can cause the heating
element to break. Use only Thermoelectric wire of
the identical specifications.
4. Occasionally check the condition of the silicon
rubber for wear or burns. A damaged silicon rubber
will affect the quality of the seal.
5. Be sure to turn OFF the power or unplug before
replacing any parts.
Control Set
Working Plate
Center Screws
Pull Rod
Pedestal
Working Tray
0421 IH-1250