Shelf Stand
Shelf Stand conditions of use
STB dimensions (W x d)
STB Weight
Maximum supported weight
How to attach to masonry walls
(This feature is not available for all models.)
Use the anchors for wall material of concrete, light
concrete, strong natural stone, soft natural stone
masonry brick and hallow block that do not crack.
Please follow the below direction
- Check the material of the wall and the thickness of the
finishing.
- When installing the product on wall material not
designated, install the product so that each fixated
location can withstand the pull out load of 70 kgf (686 N)
and shear load of 100 kgf (980 N) or above.
- Use the Ø8 mm drill bit for concrete and hammer
(Impact) drill.
1
2
STB
(Set top box)
350mm x 150mm
2.5kg
3.5kg
1
2
3
4
5
ASSEMBLING AND PREPARING
Wall mount anchor
3
4
Wall mount screw
5
6
Use a drill bit Ø8 mm to drill a hole for the anchor
location within a depth of 80 mm - 100 mm.
Clean the drilled hole.
Insert the sealed anchor to the hole. (When inserting
the anchor, use a hammer.)
Set the wall mount on the wall by aligning to the
location of the hole. and, set the angle adjusting part
to face upward.
Align the wall mount bolt to the hole and tighten it.
Then, fasten the bolts at torque of 45 kgf/cm - 60
kgf/cm.