Safety instructions
Electrical equipment must only be installed and
assembled by a qualifi ed electrician in ac-
cordance with the relevant installation stan-
dards, regulations, directives and safety and ac-
cident prevention directives of the country.
Failure to comply with these instructions may re-
sult in damage to the device, fi re or other ha-
zards.
Hazard due to electric shock. Do not operate de-
vice without application module.
Hazard of fi re. During operation with inductive
transformers, protect each transformer on the
primary side according to manufacturer's data.
Use safety transformers complying with EN
61558-2-6 (VDE 0570 Part 2-6) only.
These instructions are an integral component of
the product, and must be retained by the end
user.
Design of the device
(1)
(2)
(3)
(4)
(5)
Figure 1: Switch insert
(1) Switch insert
(2) Frame
(3) Application module
(4) Screw for dismantling protection (not R.1/R.3)
(5) Button design cover
(6) Connecting terminals
Function
Correct use
- Only suitable for use in indoor areas, no drip or
spray water
- Switching of incandescent lamps, HV halogen
lamps, fl uorescent lamps, compact fl uorescent
lamps, dimmable energy-saving lamps, 230 V
LED lamps and electronic or inductive transfor-
mers with low voltage halogen lamps
- Installation into wall box according to DIN 49073
- Operate with suitable application module (see
Chapter 6.3, „Accessories")
- Connection of extension unit push-button (NO
contact), and motion detector extension unit
No mixed load operation of capacitive and induc-
P
tive loads at the output.
Operation
These instructions describe the installation of the
switch insert. The operation and function of the
application modules are described in the instructions
of the respective application module.
The operation of extension units is only possible
P
if a cover is attached to the main unit.
Information for electricians
Installation and electrical connection
DANGER!
ç
Touching live parts can result in an
electric shock.
An electric shock can be lethal.
(6)
Disconnect the connecting cables
before working on the device and cover
all live parts in the area!
Circuiting and mounting the switch insert
A MCB max. 10 A has been installed as device
protection.
Circuit switch insert and optional extension units
according to the circuiting diagram (Figure 2 or
3).
Mount the switch insert into a wall box. The con-
necting terminals must be at the bottom.
Attach frame and application module (see in-
structions for application module).
Illuminated mechanical push-buttons must be
P
equipped with a separate N-terminal.
.
2
L
N
µ