Timed stepper relay receiver
500W flush-mounted ZigBee radio
MTR500E-UP
4820404 Relé 500W ZigBee
All UP receivers are compatible with UP transmitters
(remote controls, wall-mounted remote controls, flush-mounted transmitters).
Installation
The module must only be installed by qualified
personnel and in a place inaccessible
to the end user, in accordance with national rules of
installation.
In order to comply with safety regulations, the
module must be connected to a power line
protected upstream by a 13A circuit breaker with C
elbow.
When the receiver is switched on:
- If the receiver is not part of a ZigBee network,
its LED is lit steadily
- If the receiver is already part of a ZigBee network,
its LED is off
.
To disconnect from a ZigBee network, press and hold the
button on the receiver for at least 10 sec.
General functions
Caution: before carrying out any configuration, unlock
the product with 23 short presses. Automatic lock after 6
hours.
Presses
short (No.
Functions
of times)
20
Local control in switch mode*
21
Locking configurations
22
Flashing mode*
23
Unlocking configurations
24
Shutdown warning
25
Set duration in seconds
26
Set duration in minutes
27
Timer / relay
Saving previous status if there is no
28
network
Extended duration with double button and
34
R12M module
Factory exit reset and network connection
30
cancellation
32
Pulse mode*
33
Relay mode*
36
Reverses output between NO and NC
7/21
.
Response (no.
of flashes)
*Toggles between ON and OFF
Timer
Upon exiting the factory, timing is not active
Presses
short (No.
Duration (factory setting in minutes)
of times)
10
11
2 minutes
1
12
4 minutes
xN
2
13
8 minutes
3
14
15 minutes
4
15
30 minutes
5
16
1h (60 minutes)
6
17
2h (120 minutes)
7
18
4h (240 minutes)
19
Unlimited (no timing)
8
All configurations are preserved in the absence of mains voltage.
4
If the module is controlled by a remote control and the latter only has
this module associated with a button - in standard mode (code 1), it
2
is possible to configure the module from the remote control without
having access to the module's local button.
2
xN
3
6
Access the product page
for further information.
150m in free air space or inside a 100m²
house with perpendicular crossing of a main
wall or slab.
Disconnect the power
supply to the system
before commissioning
EN
Response (no.
of flashes)
1
2
3
4
5
6
7
8
9